FUNCTIONAL 2D AND 3D MAGNETIC-RESONANCE-IMAGING OF MOTOR CORTEX STIMULATION AT HIGH-SPATIAL-RESOLUTION USING STANDARD 1.5-T IMAGER

被引:21
作者
SCHAD, LR
WENZ, F
KNOPP, MV
BAUDENDISTEL, K
MULLER, E
LORENZ, WJ
机构
[1] Department of Radiology, German Cancer Research Center, Heidelberg
[2] Siemens Medical Division, Erlangen
关键词
MAGNETIC RESONANCE IMAGING; TECHNIQUES; FUNCTIONAL IMAGING; MOTOR CORTEX STIMULATION;
D O I
10.1016/0730-725X(94)92347-7
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This paper reports the effects of motor cortex stimulation of normal volunteers using conventional MR imaging techniques on standard 1.5 T clinical scanner. Improvement in signal-to-noise (S/N) ratio has been achieved by using a commercially available eye/ear surface coil with a loop of 8.5 cm in diameter. Magnet shimming with all first order coils was performed to the volunteer's head resulting in a magnetic field homogeneity of about 0.1-0.2 ppm. The imaging technique used was an optimized conventional 2D and 3D, first order flow rephased, gradient-echo sequence (FLASH) with fat-suppression and reduced bandwidth (16-28 Hz/pixel) and TR = 80=120 ms, TE = 60 ms, flip angle = 40 degrees, matrix = 128 x 128, FOV = 150-250 mm, slice-thickness = 2-5 mm, NEX = 1, and a total single scan time for one image df about 12-16 s. In the 3D FLASH measurements, a slab of 32 mm thickness with 16 partitions was evaluated. The motor cortex stimulation was achieved by touching each finger to thumb in a sequential, self-paced, and repetitive manner. During stimulation, an increase in signal of order 10-20% was detected in the motor and sensory cortex due to reduced partial volume effects and optimized S/N for the measurements at small voxel size. 3D FLASH imaging at high spatial resolution shows good anatomical correlation of signal increase with gray matter of the motor and sensory cortex. The reported data demonstrate the technical feasibility of functional 2D and 3D MR imaging at high spatial resolution using optimized conventional sequences and equipment.
引用
收藏
页码:9 / 15
页数:7
相关论文
共 19 条
  • [1] Ogawa, Lee, Nayak, Glynn, Oxygenation-sensitive contrast in magnetic resonance image of rodent brain at high magnetic fields, Magn. Reson. Med., 14, pp. 68-78, (1990)
  • [2] Rosen, Belliveau, Vevea, Brady, Perfusion imaging with NMR contrast agents, Magn. Reson. Med., 14, pp. 249-265, (1990)
  • [3] Belliveau, Kennedy, McKinstry, Buchbinder, Weisskoff, Cohen, Vevea, Brady, Rosen, Functional mapping of the human visual cortex by magnetic resonance imaging, Science, 254, pp. 716-719, (1991)
  • [4] Fox, Raichle, Focal physiological uncoupling of cerebral blood flow and oxidative metabolism during somatosensory stimulation in human subjects, Proc. Natl. Acad. Sci., 83, pp. 1140-1144, (1986)
  • [5] Belliveau, Functional imaging of the brain, Book of abstracts: Eleventh Annual Meeting of the Society of Magnetic Resonance in Medicine, (1992)
  • [6] Kwong, Belliveau, Chesler, Goldberg, Stern, Baker, Weisskoff, Benson, Poncelet, Hoppel, Kennedy, Turner, Cohen, Brady, Rosen, Real time imaging of perfusion change and blood oxygenation change with EPI, Book of abstracts: Eleventh Annual Meeting of the Society of Magnetic Resonance in Medicine, (1992)
  • [7] Bandettini, Wong, Hinks, Tikofsky, Hyde, Time-course gradient-echo EPI of localized signal enhancement in the human brain during task activation, Book of abstracts: Eleventh Annual Meeting of the Society of Magnetic Resonance in Medicine, (1992)
  • [8] Turner, Jezzard, Wen, Kwong, Le Bihan, Balaban, Functional mapping of the human visual cortex at 4 Tesla using deoxygenation contrast EPI, Book of abstracts: Eleventh Annual Meeting of the Society of Magnetic Resonance in Medicine, (1992)
  • [9] Bandettini, Wong, Hinks, Estkowski, Hyde, Quantification of changes in relaxation rates R2<sup>∗</sup> and R2 in activated brain tissue, Book of abstracts: Eleventh Annual Meeting of the Society of Magnetic Resonance in Medicine, (1992)
  • [10] Baker, Cohen, Stern, Kwong, Belliveau, Rosen, The effect of slice thickness and echo time on the detection of signal change during echo-planar functional neuroimaging, Book of abstracts: Eleventh Annual Meeting of the Society of Magnetic Resonance in Medicine, (1992)