NEW CHAMBER FOR FLOW CYTOMETRIC ANALYSIS OVER AN EXTENDED RANGE OF STREAM-VELOCITY AND APPLICATION TO CELL-ADHESION MEASUREMENTS

被引:5
作者
AMBLARD, F
CANTIN, C
DURAND, J
FISCHER, A
SEKALY, R
AUFFRAY, C
机构
[1] CNRS, EMBRYOL CELLULAIRE & MOLEC LAB, F-94130 NOGENT SUR MARNE, FRANCE
[2] COLL FRANCE, F-94130 NOGENT SUR MARNE, FRANCE
[3] HOP NECKER ENFANTS MALAD, INSERM, U132, F-75730 PARIS 15, FRANCE
[4] INST RECH CLIN MONTREAL, MONTREAL H2W 1R7, QUEBEC, CANADA
来源
CYTOMETRY | 1992年 / 13卷 / 01期
关键词
LOW VELOCITY FLOW CYTOMETRY; FLOW CHAMBER; FLUID MECHANICS; HYDRODYNAMIC STRESS; HYDRODYNAMIC FOCUSING;
D O I
10.1002/cyto.990130105
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
When analyzed in a flow cytometer, particles are suddenly accelerated to high velocities (1-10 m.s-1) over very short distances. This feature is essential to obtain high analysis rates and low coincidence levels, but translates into very strong velocity gradients (> 10(5) s-1): particles experience strong hydrodynamic stresses that elongate them and tend to dissociate weakly associated complexes. In order to analyze fragile conjugates formed by heterotypic adhesion between two cell types, a flow cytometer was modified to make hydrodynamic stress not only much weaker but also adjustable. A new and easily adaptable flow cell was designed for the instruments of the FACS(TM) series; it provided satisfactory hydrodynamic conditions on a wide continous range of flow rates. Accompanying electronic adaptations permitted standard analysis between 0.01 and 10 m.s-1. At 0.01 m.s-1, the velocity gradient roughly amounts to 50 s-1. Conjugates formed by the adhesion between human B and resting T lymphocytes, disrupted. in conventional flow cytometers, could be detected and precisely quantified provided analysis velocity was kept below 0.1 m.s-1. We conclude that low velocity flow cytometry makes possible the quantification of weak intercellular adhesion phenomena, and is potentially useful for the future development of new biomechanical techniques and other applications.
引用
收藏
页码:15 / 22
页数:8
相关论文
共 18 条
  • [1] T-CELL RECEPTOR CROSS-LINKING TRANSIENTLY STIMULATES ADHESIVENESS THROUGH LFA-1
    DUSTIN, ML
    SPRINGER, TA
    [J]. NATURE, 1989, 341 (6243) : 619 - 624
  • [2] DETECTION AND DISCRIMINATION OF INDIVIDUAL VIRUSES BY FLOW CYTOMETRY
    HERCHER, M
    MUELLER, W
    SHAPIRO, HM
    [J]. JOURNAL OF HISTOCHEMISTRY & CYTOCHEMISTRY, 1979, 27 (01) : 350 - 352
  • [3] QUANTUM EFFICIENCY INDEPENDENCE OF TIME INTEGRATED EMISSION FROM A FLUORESCENT MOLECULE
    HIRSCHFELD, T
    [J]. APPLIED OPTICS, 1976, 15 (12): : 3135 - 3139
  • [4] OPTICAL MICROSCOPIC OBSERVATION OF SINGLE SMALL MOLECULES
    HIRSCHFELD, T
    [J]. APPLIED OPTICS, 1976, 15 (12): : 2965 - 2966
  • [5] Kachel V., 1990, FLOW CYTOMETRY SORTI, P27
  • [6] LUCE G G, 1985, Biotechniques, V3, P270
  • [7] REGULATION OF T-HELPER-B-LYMPHOCYTE ADHESION THROUGH CD4-HLA CLASS-II INTERACTION
    MAZEROLLES, F
    AMBLARD, F
    LUMBROSO, C
    LECOMTE, O
    VANDEMOORTELE, PF
    BARBAT, C
    PIATIERTONNEAU, D
    AUFFRAY, C
    FISCHER, A
    [J]. EUROPEAN JOURNAL OF IMMUNOLOGY, 1990, 20 (03) : 637 - 644
  • [8] NGUYEN DC, 1987, ANAL CHEM, V59, P2158, DOI 10.1021/ac00144a032
  • [9] LEUKOCYTE ADHESION TO CELLS - MOLECULAR-BASIS, PHYSIOLOGICAL RELEVANCE, AND ABNORMALITIES
    PATARROYO, M
    MAKGOBA, MW
    [J]. SCANDINAVIAN JOURNAL OF IMMUNOLOGY, 1989, 30 (02) : 129 - 164
  • [10] Pinkel D., 1985, FLOW CYTOMETRY INSTR, P77