RELATIONSHIP BETWEEN ARTERIAL CARBON-DIOXIDE AND END-TIDAL CARBON-DIOXIDE WHEN A NASAL SAMPLING PORT IS USED

被引:26
作者
MCNULTY, SE
ROY, J
TORJMAN, M
SELTZER, JL
机构
[1] Department of Anesthesiology, Jefferson Medical College, Thomas Jefferson University, Philadelphia, PA
来源
JOURNAL OF CLINICAL MONITORING | 1990年 / 6卷 / 02期
关键词
Carbon dioxide: arterial; end-tidal; Measurement techniques: capnography; Monitoring: carbon dioxide; capnography;
D O I
10.1007/BF02828284
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
End-tidal carbon dioxide (ETCO2) values obtained from awake nonintubated patients may prove to be useful in estimating a patient's ventilatory status. This study examined the relationship between arterial carbon dioxide tension (PaCO2) and ETCO2 during the preoperative period in 20 premedicated patients undergoing various surgical procedures. ETCO2 was sampled from a 16-gauge intravenous catheter pierced through one of the two nasal oxygen prongs and measured at various oxygen flow rates (2, 4, and 6 L/min) by an on-line ETCO2 monitor with analog display. Both peak and time-averaged values for ETCO2 were recorded. The results showed that the peak ETCO2 values (mean = 38.8 mm Hg) correlated more closely with the PaCO2 values (mean = 38.8 mm Hg; correlation coefficient r = 0.76) than did the average ETCO2 values irrespective of the oxygen flow rates. The time-averaged PaCO2-ETCO2 difference was significantly greater than the PaCO2-peak ETCO2 difference (P < 0.001). Values for subgroups within the patient population were also analyzed, and it was shown that patients with minute respiratory rates greater than 20 but less than 30 and patients age 65 years or older did not differ from the overall studied patient population with regard to PaCO2-ETCO2 difference. A small subset of patients with respiratory rates of 30/ min or greater (n = 30) did show a significant increase in the PaCO2-ETCO2 difference (P < 0.001). It was concluded that under the conditions of this study, peak ETCO2 values did correlate with PaCO2 values and were not significantly affected by oxygen flow rate. However, obtaining peak ETCO2 values is clinically more difficult, especially when partial air-way obstruction is present. © 1990 Little, Brown and Company.
引用
收藏
页码:93 / 98
页数:6
相关论文
共 22 条
[1]  
Shankar K.B., Moscley H., Kumar Y., Vemula V., Arterial to end tidal carbon dioxide tension difference during caesarean section anesthesia, Anaesthesia, 41, pp. 698-702, (1986)
[2]  
Badgwell J.M., McLeod M.E., Lerman J., Creighton R.E., End-tidal PCO<sub>2</sub> measurements sampled at the distal and proximal ends of the endotracheal tube in infants and children, Anesth Analg, 66, pp. 959-964, (1987)
[3]  
McEvedy B.A.B., McLeod M.E., Mulera M., Et al., End-tidal, transcutaneous, and arterial PCO<sub>2</sub> measurements in critically ill neonates: a comparative study, Anesthesiology, 69, pp. 112-116, (1988)
[4]  
Ibarra E., Lees D.E., Mass spectrometer monitoring of patients with regional anesthesia, Anesthesiology, 63, pp. 572-573, (1985)
[5]  
Norman E.A., Zeig N.J., Ahmad I., Better designs for mass spectrometer monitoring of the awake patient, Anesthesiology, 64, (1986)
[6]  
Huntington C.T., King H.K., A simpler design for mass spectrometer monitoring of the awake patient, Anesthesiology, 65, pp. 565-566, (1986)
[7]  
Pressman M.A., A simple method of measuring ETCO<sub>2</sub> during MAC and major regional anesthesia, Anesth Analg, 67, pp. 905-906, (1988)
[8]  
Bowe E.A., Boysen P.G., Broome J.A., Klein E.F., Accurate determination of end-tidal carbon dioxide during administration of oxygen by nasal cannula, J Clin Monit, 5, pp. 105-110, (1989)
[9]  
Goldman J.M., A simple, easy, and inexpensive method for monitoring ETCO<sub>2</sub> through the nasal cannula, Anesthesiology, 67, (1987)
[10]  
Louwsma D.L., Silverman D.G., Reproducibility of end tidal CO<sub>2</sub> measurements in sedated patients receiving supplemental O<sub>2</sub> by nasal cannula (abstract), Anesthesiology, 69, (1988)