HIGH-RESOLUTION CT OF THE TEMPORAL BONE - A MODIFIED BASE-LINE

被引:22
作者
TORIZUKA, T [1 ]
HAYAKAWA, K [1 ]
SATOH, Y [1 ]
TANAKA, F [1 ]
SAITOH, H [1 ]
OKUNO, Y [1 ]
OGURA, A [1 ]
NAKAYAMA, Y [1 ]
KONISHI, J [1 ]
机构
[1] KYOTO CITY HOSP,DEPT RADIOL,KYOTO,JAPAN
关键词
EAR; CT; RADIATIONS; EXPOSURE TO PATIENTS AND PERSONNEL; TEMPORAL BONE;
D O I
10.1148/radiology.184.1.1609065
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
High-resolution computed tomography (CT) of the temporal bone, particularly axial scanning on a baseline parallel to the orbitomeatal line, produces radiation exposure to the patient's lenses. The authors evaluated the radiation dose to the lens and the visualization of temporal bone structures with use of scanning along the orbitomeatal line and on a line parallel to the hard palate. Evaluation of visualization was performed by five radiologists, with high-resolution CT scans of 45 healthy patients, and the chi(2) test was performed for comparison. The change of the baseline from the orbitomeatal line to a line parallel to the hard palate decreased the radiation dose to the lens from 12.7 cGy to 0.274 cGy and improved visualization of the stapes superstructure and the tympanic portion of the facial nerve canal, although visualization of the incus body, incudostapedial joint, lateral semicircular canal, and oval window was of equal quality. Therefore, the authors recommend a new baseline parallel to the hard palate for use at high-resolution CT of the temporal bone.
引用
收藏
页码:109 / 111
页数:3
相关论文
共 16 条
[1]  
BROGAN M, 1989, SEMIN ULTRASOUND CT, V10, P178
[2]  
CHAKERES DW, 1984, RADIOL CLIN N AM, V22, P3
[3]   A SYSTEMATIC TECHNIQUE FOR COMPREHENSIVE EVALUATION OF THE TEMPORAL BONE BY COMPUTED-TOMOGRAPHY [J].
CHAKERES, DW ;
SPIEGEL, PK .
RADIOLOGY, 1983, 146 (01) :97-106
[4]  
ISONO M, 1990, ACTA RADIOL, V31, P27
[5]  
JACKLER RK, 1984, LARYNGOSCOPE, V94, P746
[6]   CHOLESTEATOMAS OF THE TEMPORAL BONE - ROLE OF COMPUTED-TOMOGRAPHY [J].
JOHNSON, DW ;
VOORHEES, RL ;
LUFKIN, RB ;
HANAFEE, W ;
CANALIS, R .
RADIOLOGY, 1983, 148 (03) :733-737
[7]  
JOHNSON DW, 1984, RADIOL CLIN N AM, V22, P67
[8]   HIGH-RESOLUTION COMPUTED-TOMOGRAPHY OF THE TEMPORAL BONE [J].
SHAFFER, KA ;
HAUGHTON, VM ;
WILSON, CR .
RADIOLOGY, 1980, 134 (02) :409-414
[9]   HIGH-RESOLUTION COMPUTED-TOMOGRAPHY OF THE MIDDLE-EAR AND MASTOID .3. SURGICALLY ALTERED ANATOMY AND PATHOLOGY [J].
SWARTZ, JD ;
GOODMAN, RS ;
RUSSELL, KB ;
LADENHEIM, SE ;
WOLFSON, RJ .
RADIOLOGY, 1983, 148 (02) :461-464
[10]   SYNTHETIC OSSICULAR REPLACEMENTS - NORMAL AND ABNORMAL CT APPEARANCE [J].
SWARTZ, JD ;
BERGER, AS ;
ZWILLENBERG, S ;
GRANOFF, DW ;
POPKY, GL .
RADIOLOGY, 1987, 163 (03) :766-768