摘要
The application of inductively coupled plasma mass spectrometry (ICP-MS) and glow discharge mass spectrometry (GD-MS) to the analysis of aluminium alloys is presented. The spectral characteristics of these two techniques are compared and contrasted. For the most part GD mass spectra are simpler than ICP mass spectra in that species originating from the components of air, water and solution solutes are essentially absent in GD spectra. However, GD spectra show the presence of multiply charged Ar species, and matrix and analyte based argide species are more prevalent than oxide species, the opposite being the case with the ICP. For both techniques, potential spectral interferences are evaluated and matrix effects are illustrated. For ICP-based analyses, it is shown that matrix effects can be minimized by adjustment of the nebulizer gas flow rate and by the use of an internal standard which is easy to add to the dissolved samples. For GD-based analyses, a matrix effect exists between low and high alloy aluminium samples and it is shown that the signal from AlAr can be used as an internal standard to minimize this matrix effect. Finally both techniques were applied to the analysis of a range of Alcan and Alcoa aluminium standards.
引用
收藏
页码:823 / 831
页数:9
相关论文
共 19 条
[1]   GLOW-DISCHARGE - CONSIDERATIONS AS A VERSATILE ANALYTICAL SOURCE - PLENARY LECTURE [J].
HARRISON, WW .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1992, 7 (02) :75-79
[2]  
Horlick G., 1992, INDUCTIVELY COUPLED, P551
[3]  
KAWAGUCHI H, 1992, 1992 WINT C PLASM SP
[4]   JET-ENHANCED SPUTTERING CELL AS AN ION-SOURCE FOR MASS-SPECTROMETRY [J].
KIM, HJ ;
PIEPMEIER, EH ;
BECK, GL ;
BRUMBAUGH, GG ;
FARMER, OT .
ANALYTICAL CHEMISTRY, 1990, 62 (06) :639-643
[5]   STUDY OF MOLECULAR INTERFERENCES IN GLOW-DISCHARGE MASS-SPECTROMETRY [J].
KING, FL ;
MCCORMACK, AL ;
HARRISON, WW .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1988, 3 (06) :883-886
[6]  
KOPPENAAL DW, 1990, ANAL CHEM, V62, pR303, DOI 10.1021/ac00211a015
[7]  
MARCUS RK, 1989, 657 PAP
[8]  
MCLAREN JW, 1992, ATOM SPECTROSC, V13, P81
[9]   DESIGN AND CHARACTERIZATION OF GLOW-DISCHARGE DEVICES AS COMPLEMENTARY SOURCES FOR AN ICP MASS-SPECTROMETER [J].
SHAO, Y ;
HORLICK, G .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1991, 46 (02) :165-174
[10]  
SHILOMATSU HM, 1988, NUCL INSTRUM METH A, V280, P488