RED-CELL LOSS FOLLOWING ORTHOPEDIC-SURGERY - THE CASE AGAINST POSTOPERATIVE BLOOD SALVAGE

被引:30
作者
UMLAS, J
FOSTER, RR
DALAL, SA
OLEARY, SM
GARCIA, L
KRUSKALL, MS
机构
[1] MT AUBURN HOSP,DEPT ORTHOPED SURG,CAMBRIDGE,MA 02138
[2] MT AUBURN HOSP,DEPT ANESTHESIA,CAMBRIDGE,MA 02138
[3] BETH ISRAEL HOSP,DEPT PATHOL,BOSTON,MA 02215
[4] BETH ISRAEL HOSP,DEPT MED,BOSTON,MA 02215
[5] HARVARD UNIV,SCH MED,BOSTON,MA
关键词
D O I
10.1046/j.1537-2995.1994.34594249051.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Expensive devices have been developed for the collection and transfusion of blood salvaged after hip or knee arthroplasty.
引用
收藏
页码:402 / 406
页数:5
相关论文
共 21 条
[1]   SALVAGE AND REINFUSION OF POSTOPERATIVE SANGUINEOUS WOUND DRAINAGE - A PRELIMINARY-REPORT [J].
CLEMENTS, DH ;
SCULCO, TP ;
BURKE, SW ;
MAYER, K ;
LEVINE, DB .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1992, 74A (05) :646-651
[2]  
Gannon D M, 1991, J Arthroplasty, V6, P109, DOI 10.1016/S0883-5403(11)80004-5
[3]   RED BLOOD-CELL MASS IN AUTOLOGOUS AND HOMOLOGOUS BLOOD UNITS - IMPLICATIONS FOR RISK BENEFIT ASSESSMENT OF AUTOLOGOUS BLOOD CROSSOVER AND DIRECTED BLOOD-TRANSFUSION [J].
GOODNOUGH, LT ;
BRAVO, JR ;
HSUEH, YS ;
KEATING, LJ ;
BRITTENHAM, GM .
TRANSFUSION, 1989, 29 (09) :821-822
[4]  
Groh G I, 1990, J Arthroplasty, V5, P281, DOI 10.1016/S0883-5403(08)80084-8
[5]  
HALLETT JW, 1987, J VASC SURG, V5, P601
[6]   A RANDOMIZED TRIAL ON THE EFFICACY OF AN AUTOLOGOUS BLOOD DRAINAGE AND TRANSFUSION DEVICE IN PATIENTS UNDERGOING ELECTIVE KNEE ARTHROPLASTY [J].
HEDDLE, NM ;
BROX, WT ;
KLAMA, LN ;
DICKSON, LL ;
LEVINE, MN .
TRANSFUSION, 1992, 32 (08) :742-746
[7]   THE EFFICACY OF POSTOPERATIVE AUTO-TRANSFUSION IN PATIENTS UNDERGOING CARDIAC OPERATIONS [J].
JOHNSON, RG ;
ROSENKRANTZ, KR ;
PRESTON, RA ;
HOPKINS, C ;
DAGGETT, WM .
ANNALS OF THORACIC SURGERY, 1983, 36 (02) :173-179
[8]  
KRISTENSEN PW, 1992, ACTA ORTHOP SCAND, V62, P377
[9]   UTILIZATION AND EFFECTIVENESS OF A HOSPITAL AUTOLOGOUS PREOPERATIVE BLOOD-DONOR PROGRAM [J].
KRUSKALL, MS ;
GLAZER, EE ;
LEONARD, SS ;
WILLSON, SC ;
PACINI, DG ;
DONOVAN, LM ;
RANSIL, BJ .
TRANSFUSION, 1986, 26 (04) :335-340
[10]   THE EFFECTS OF INTRAOPERATIVE BLOOD SALVAGE AND INDUCED HYPOTENSION ON TRANSFUSION REQUIREMENTS DURING SPINAL SURGICAL-PROCEDURES [J].
LENNON, RL ;
HOSKING, MP ;
GRAY, JR ;
KLASSEN, RA ;
POPOVSKY, MA ;
WARNER, MA .
MAYO CLINIC PROCEEDINGS, 1987, 62 (12) :1090-1094