EFFECT OF AICD PATCH ELECTRODES ON THE DIASTOLIC PRESSURE VOLUME CURVE IN PIGS

被引:11
作者
AUTERI, JS [1 ]
JEEVANANDAM, V [1 ]
BIELEFELD, MR [1 ]
SANCHEZ, JA [1 ]
SPOTNITZ, HM [1 ]
机构
[1] COLUMBIA UNIV COLL PHYS & SURG,DEPT SURG,630 W 168TH ST,NEW YORK,NY 10032
关键词
D O I
10.1016/0003-4975(91)91280-9
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Although the automatic implantable cardioverter defibrillator (AICD) is effective against malignant ventricular arrhythmias, the effects of AICD patches on left ventricular diastolic properties have not been defined. Accordingly, extrapericardial (group E, n = 5) or intrapericardial (group I, n = 6) AICD patches were implanted through a median sternotomy in 11 anesthetized pigs. Six weeks later, using a left thoracotomy, the hearts were arrested with hypothermic cardioplegia. A balloon catheter was inserted into the left ventricle through the aortic root, and pressure-volume curves were measured before and after sequential removal of patches and pericardium. A dense intrapericardial fibrotic reaction in group I was not present in group E. Normalized left ventricular filling volumes in group E were significantly larger at pressures of 5.1 to 10, 15.1 to 20, and 20.1 to 28 mm Hg compared with group I (p < 0.05). We conclude that intrapericardial AICD patches adversely affect left ventricular diastolic pressure-volume relations and recommend that AICD patches be placed in the extrapericardial location clinically whenever possible.
引用
收藏
页码:1052 / 1057
页数:6
相关论文
共 20 条
[1]   ACUTE HEMODYNAMIC INTERVENTIONS SHIFT DIASTOLIC PRESSURE-VOLUME CURVE IN MAN [J].
ALDERMAN, EL ;
GLANTZ, SA .
CIRCULATION, 1976, 54 (04) :662-671
[2]   EFFECT OF ELECTROPHYSIOLOGICAL TESTING ON EJECTION FRACTION DURING CARDIOVERTER DEFIBRILLATOR IMPLANTATION [J].
ANTUNES, ML ;
SPOTNITZ, HM ;
LIVELLI, FD ;
STEINBERG, JS ;
BIGGER, JT .
ANNALS OF THORACIC SURGERY, 1988, 45 (03) :315-318
[3]   SILICONE GRANULOMA FOLLOWING CLOSED CAPSULOTOMY OF MAMMARY PROSTHESIS [J].
APESOS, J ;
POPE, TL .
ANNALS OF PLASTIC SURGERY, 1985, 14 (05) :403-406
[4]   CLINICAL-EXPERIENCE, COMPLICATIONS, AND SURVIVAL IN 70 PATIENTS WITH THE AUTOMATIC IMPLANTABLE CARDIOVERTER DEFIBRILLATOR [J].
ECHT, DS ;
ARMSTRONG, K ;
SCHMIDT, P ;
OYER, PE ;
STINSON, EB ;
WINKLE, RA .
CIRCULATION, 1985, 71 (02) :289-296
[5]   PERICARDIAL ADAPTATIONS DURING CHRONIC CARDIAC DILATION IN DOGS [J].
FREEMAN, GL ;
LEWINTER, MM .
CIRCULATION RESEARCH, 1984, 54 (03) :294-300
[6]   DETERMINANTS OF LEFT-VENTRICULAR FILLING AND OF THE DIASTOLIC PRESSURE-VOLUME RELATION [J].
GILBERT, JC ;
GLANTZ, SA .
CIRCULATION RESEARCH, 1989, 64 (05) :827-852
[7]   PERICARDIUM SUBSTANTIALLY AFFECTS LEFT-VENTRICULAR DIASTOLIC PRESSURE-VOLUME RELATIONSHIP IN DOG [J].
GLANTZ, SA ;
MISBACH, GA ;
MOORES, WY ;
MATHEY, DG ;
LEKVEN, J ;
STOWE, DF ;
PARMLEY, WW ;
TYBERG, JV .
CIRCULATION RESEARCH, 1978, 42 (03) :433-441
[8]   FACTORS WHICH AFFECT DIASTOLIC PRESSURE-VOLUME CURVE [J].
GLANTZ, SA ;
PARMLEY, WW .
CIRCULATION RESEARCH, 1978, 42 (02) :171-180
[9]  
JANICKI JS, 1980, FED PROC, V39, P133
[10]   RIGHT MINI-THORACOTOMY - AN ADJUNCT TO LEFT SUBCOSTAL AUTOMATIC IMPLANTABLE CARDIOVERTER DEFIBRILLATOR IMPLANTATION [J].
LAWRIE, GM ;
KAUSHIK, RR ;
PACIFICO, A .
ANNALS OF THORACIC SURGERY, 1989, 47 (05) :780-781