2-TO-ONE DISCREPANCY BETWEEN MEASURED AND PREDICTED PERFORMANCE OF A LOW-ENERGY OFFICE BUILDING - INSIGHTS FROM A RECONCILIATION BASED ON THE DOE-2 MODEL

被引:133
作者
NORFORD, LK
SOCOLOW, RH
HSIEH, ES
SPADARO, GV
机构
[1] Center for Energy and Environmental Studies, Princeton University, Princeton, NJ
关键词
CALIBRATION; ENERGY CONSUMPTION; OFFICE BUILDING; HVAC CONTROLS; OCCUPANT BEHAVIOR;
D O I
10.1016/0378-7788(94)90005-1
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Computer models of building energy use, if calibrated with measured data, offer a means of assessing retrofit savings, optimizing HVAC operation (on- or off-line), and presenting energy-consumption feedback to building operators. The calibration process itself can pinpoint differences between how a building was designed to perform and how it is actually functioning. Our initial goal was to identify why the actual annual energy consumption of an office building was 325 kWh/m(2), over twice the predicted value of 125 kWh/m(2). Part of our effort to understand its performance involved calibrating a DOE-2 model prepared at the design stage. In the process, we formulated calibration guidelines and developed insights that may be of use to others. Of particular interest are the major sources of the wide discrepancy between predicted and actual energy use, Unanticipated tenant energy consumption, both during the day and the night, contributed 64% of the two-fold increase. Heating, ventilation and air-conditioning (HVAC) equipment operation beyond the expected 10 h per weekday contributed 24%. We attributed the remaining 12% to HVAC equipment not operating up to specification; building conductive heat loss in excess of the design-stage prediction; and minimum outdoor-air intake differing from the design value. The calibration process involved working on major input parameters independently of the others, then combining the results into one simulation. The calibrated model accounted for 94% of measured site energy for the building.
引用
收藏
页码:121 / 131
页数:11
相关论文
共 24 条
[1]  
Kaplan, Jones, Jansen, DOE-2.1C model calibration with monitored end-use data, Proc. ACEEE 1990 Summer Study on Energy Efficiency in Buildings, 10, (1990)
[2]  
Kaplan, McFerren, Jansen, Pratt, Reconciliation of a DOE2.1C model with monitored end-use data for a small office building, ASHRAE Trans., 96, (1990)
[3]  
Diamond, Piette, Nordman, de Buen, Harris, The performance of the Energy Edge buildings: energy use and savings, Proc. ACEEE 1992 Summer Study on Energy Efficiency in Buildings, 3, (1992)
[4]  
Haberl, Bronson, Hinchey, O'Neal, Graphical tools to help calibrate the DOE-2 simulation program, ASHRAE J., (1993)
[5]  
Clarke, Strachan, Pernot, An approach to the calibration of building energy simulation models, ASHRAE Trans., 99, (1993)
[6]  
Carroll, Hitchcock, Tuning simulated building descriptions to match actual utility data: methods and implementation, ASHRAE Trans., 99, (1993)
[7]  
Burch, Subbarao, Lekov, Warren, Norford, Short-term energy monitoring in a large commercial office building, ASHRAE Trans., 96, (1990)
[8]  
Hsieh, Calibrated computer models of commercial buildings and their role in building design and operation, M.S. Thesis, (1988)
[9]  
Norford, Rabl, Ryan, Spadaro, Socolow, Energy use in the Enerplex Office Buildings: a progress report, Proc. ACEEE 1986 Summer Study on Energy Efficiency in Buildings, (1986)
[10]  
Nairn, Enerplex: office complex exploring sophisticated energy solutions, Archit. Rec., 170, (1982)