RESPONSES AND CALIBRATION OF AMPEROMETRIC GLUCOSE SENSORS IMPLANTED IN THE SUBCUTANEOUS TISSUE OF MAN

被引:36
作者
PICKUP, JC
CLAREMONT, DJ
SHAW, GW
机构
[1] Division of Chemical Pathology, United Medical and Dental Schools, Guy's Hospital, London
关键词
BIOSENSOR; ENZYME ELECTRODE; GLUCOSE SENSOR;
D O I
10.1007/BF00572858
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Glucose sensors based on immobilized glucose oxidase and hydrogen peroxide detection at a platinum base electrode were constructed and studied before, during and after implantation into the subcutaneous tissue of 11 non-diabetic subjects. A 75-g oral glucose load was given to elevate the blood glucose concentration. Seven of 14 sensors responded to the oral glucose administration with an increase in current and the output of the remainder was unchanged by the glucose load. Apparent subcutaneous glucose levels calculated from the pre-implantation calibration were a mean 58% of the plasma glucose values at baseline. A two-point in vivo calibration using paired current and glucose readings at baseline and at the maximum glucose and current after glucose ingestion showed a significantly reduced sensitivity in vivo compared with pre-implantation values (mean +/- SEM 52 +/- 21.5 vs 369 +/- 127 pA/mmol-1 per litre, P = 0.003). Recalibration of the subcutaneous glucose concentrations using the in vivo calibration sensitivity and extrapolated background current (I0) gave values similar to those in plasma. The sensitivity of five sensors recalibrated in vitro after explantation was also reduced compared with pre-implantation levels and not significantly different from the in vivo characteristics. Responding and non-responding sensors did not differ with respect to preimplantation I0, sensitivity or response time. However, provisional examination of some explanted sensors by scanning electron microscopy showed coating by cellular and other amorphous material in the non-functioning electrodes. We conclude that the sensitivity of glucose sensors of this design is markedly reduced, sometimes to zero, on implantation in the subcutaneous tissue of humans. Though several factors may contribute to this effect, a likely explanation is coating of or interaction with the sensor by components of the biological matrix.
引用
收藏
页码:143 / 148
页数:6
相关论文
共 27 条
[1]  
ABEL P, 1984, BIOMED BIOCHIM ACTA, V43, P577
[2]   APPLICATION OF CHRONIC INTRAVASCULAR BLOOD-GLUCOSE SENSOR IN DOGS [J].
ARMOUR, JC ;
LUCISANO, JY ;
MCKEAN, BD ;
GOUGH, DA .
DIABETES, 1990, 39 (12) :1519-1526
[3]   DETERMINATION OF PHYSIOLOGICAL LEVELS OF GLUCOSE IN AN AQUEOUS MATRIX WITH DIGITALLY FILTERED FOURIER-TRANSFORM NEAR-INFRARED SPECTRA [J].
ARNOLD, MA ;
SMALL, GW .
ANALYTICAL CHEMISTRY, 1990, 62 (14) :1457-1464
[4]  
BARTLETT PN, 1990, BIOSENSORS PRACTICAL, P47
[5]  
BESSMAN SP, 1981, T AM SOC ART INT ORG, V27, P7
[6]   DESIGN AND INVITRO STUDIES OF A NEEDLE-TYPE GLUCOSE SENSOR FOR SUBCUTANEOUS MONITORING [J].
BINDRA, DS ;
ZHANG, YN ;
WILSON, GS ;
STERNBERG, R ;
THEVENOT, DR ;
MOATTI, D ;
REACH, G .
ANALYTICAL CHEMISTRY, 1991, 63 (17) :1692-1696
[7]   MICRODIALYSIS OF SUBCUTANEOUS ADIPOSE-TISSUE INVIVO FOR CONTINUOUS GLUCOSE MONITORING IN MAN [J].
BOLINDER, J ;
HAGSTROM, E ;
UNGERSTEDT, U ;
ARNER, P .
SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1989, 49 (05) :465-474
[8]   INVIVO MEASUREMENT OF SUBCUTANEOUS GLUCOSE-CONCENTRATIONS WITH AN ENZYMATIC GLUCOSE SENSOR AND A WICK METHOD [J].
BRUCKEL, J ;
KERNER, W ;
ZIER, H ;
STEINBACH, G ;
PFEIFFER, EF .
KLINISCHE WOCHENSCHRIFT, 1989, 67 (09) :491-495
[9]   SUBCUTANEOUS IMPLANTATION OF A FERROCENE-MEDIATED GLUCOSE SENSOR IN PIGS [J].
CLAREMONT, DJ ;
SAMBROOK, IE ;
PENTON, C ;
PICKUP, JC .
DIABETOLOGIA, 1986, 29 (11) :817-821
[10]   FUNDAMENTALS OF GLUCOSE SENSORS [J].
FISCHER, U .
DIABETIC MEDICINE, 1991, 8 (04) :309-321