QUANTITATION OF ANTEGRADE AND RETROGRADE BLOOD-FLOW IN THE HUMAN AORTA BY MAGNETIC-RESONANCE VELOCITY MAPPING

被引:115
作者
BOGREN, HG [1 ]
KLIPSTEIN, RH [1 ]
FIRMIN, DN [1 ]
MOHIADDIN, RH [1 ]
UNDERWOOD, SR [1 ]
REES, RSO [1 ]
LONGMORE, DB [1 ]
机构
[1] NATL HEART & CHEST HOSP,MAGNET RESONANCE UNIT,LONDON,ENGLAND
关键词
D O I
10.1016/0002-8703(89)90399-2
中图分类号
R5 [内科学];
学科分类号
1002 [临床医学]; 100201 [内科学];
摘要
引用
收藏
页码:1214 / 1222
页数:9
相关论文
共 34 条
[1]
AORTIC DISSECTION - MAGNETIC-RESONANCE IMAGING [J].
AMPARO, EG ;
HIGGINS, CB ;
HRICAK, H ;
SOLLITTO, R .
RADIOLOGY, 1985, 155 (02) :399-406
[2]
MAGNETIC-RESONANCE VELOCITY MAPPING IN AORTIC DISSECTION [J].
BOGREN, HG ;
UNDERWOOD, SR ;
FIRMIN, DN ;
MOHIADDIN, RH ;
KLIPSTEIN, RH ;
REES, RSO ;
LONGMORE, DB .
BRITISH JOURNAL OF RADIOLOGY, 1988, 61 (726) :456-462
[3]
EVALUATION OF THE AORTA IN THE MARFAN-SYNDROME BY MAGNETIC-RESONANCE-IMAGING [J].
BOXER, RA ;
LACORTE, MA ;
SINGH, S ;
DAVIS, J ;
GOLDMAN, M ;
STEIN, HL .
AMERICAN HEART JOURNAL, 1986, 111 (05) :1001-1002
[4]
MEASUREMENT OF FLOW WITH NMR IMAGING USING A GRADIENT PULSE AND PHASE DIFFERENCE TECHNIQUE [J].
BRYANT, DJ ;
PAYNE, JA ;
FIRMIN, DN ;
LONGMORE, DB .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1984, 8 (04) :588-593
[5]
MAGNETIC-RESONANCE-IMAGING OF THORACIC AORTIC-ANEURYSMS - COMPARISON WITH OTHER IMAGING METHODS [J].
DINSMORE, RE ;
LIBERTHSON, RR ;
WISMER, GL ;
MILLER, SW ;
LIU, P ;
THOMPSON, R ;
MCLOUD, TC ;
MARSHALL, J ;
SAINI, S ;
STRATEMEIER, EJ ;
OKADA, RD ;
BRADY, TJ .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1986, 146 (02) :309-314
[6]
INFLUENCE OF SAMPLING SITE AND FLOW AREA ON CARDIAC-OUTPUT MEASUREMENTS BY DOPPLER ECHOCARDIOGRAPHY [J].
DITTMANN, H ;
VOELKER, W ;
KARSCH, KR ;
SEIPEL, L .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1987, 10 (04) :818-823
[7]
INVIVO VALIDATION OF MR VELOCITY IMAGING [J].
FIRMIN, DN ;
NAYLER, GL ;
KLIPSTEIN, RH ;
UNDERWOOD, SR ;
REES, RSO ;
LONGMORE, DB .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1987, 11 (05) :751-756
[8]
THE EFFECT OF VARIATIONS ON PULSED DOPPLER SAMPLING SITE ON CALCULATION OF CARDIAC-OUTPUT - AN EXPERIMENTAL-STUDY IN OPEN-CHEST DOGS [J].
FISHER, DC ;
SAHN, DJ ;
FRIEDMAN, MJ ;
LARSON, D ;
VALDESCRUZ, LM ;
HOROWITZ, S ;
GOLDBERG, SJ ;
ALLEN, HD .
CIRCULATION, 1983, 67 (02) :370-376
[9]
FUNCTIONAL-EVALUATION OF THE HEART WITH MAGNETIC-RESONANCE IMAGING [J].
HIGGINS, CB ;
HOLT, W ;
PFLUGFELDER, P ;
SECHTEM, U .
MAGNETIC RESONANCE IN MEDICINE, 1988, 6 (02) :121-139
[10]
A COMPARISON BETWEEN SINGLE GATE AND MULTIGATE ULTRASONIC DOPPLER MEASUREMENTS FOR THE ASSESSMENT OF THE VELOCITY PATTERN IN THE HUMAN ASCENDING AORTA [J].
JENNI, R ;
VIELI, A ;
RUFFMANN, K ;
KRAYENBUEHL, HP ;
ANLIKER, M .
EUROPEAN HEART JOURNAL, 1984, 5 (11) :948-953