X-RAY TUBE POTENTIAL, FILTRATION, AND DETECTOR CONSIDERATIONS IN DUAL-ENERGY CHEST RADIOGRAPHY

被引:39
作者
GAUNTT, DM [1 ]
BARNES, GT [1 ]
机构
[1] UNIV ALABAMA,HOSP & CLIN,DEPT RADIOL,BIRMINGHAM,AL 35233
关键词
D O I
10.1118/1.597373
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
The effect of x-ray tube potential and prepatient and interdetector filtration in single exposure dual energy chest imaging has been studied employing a carefully benchmarked model. The analysis utilized published methodology. Noise in simulated lung and mediastinum fields of the aluminum (bone) and Lucite (Soft tissue) images were studied at fixed entrance skih exposure (ESE) for commonly employed sandwich detector and sandwich imaging plate configurations. Our results indicate noise in the lung increases slowly with tube potential above 120 kVp, while noise ir; the mediastinum decreases rapidly. Also, at high tube potential (greater than or equal to 120 kVp) adding moderate amounts of prepatient K-edge filtration (congruent to 100 mg/cm(2)) while optimizing imaging conditions for the lung tends to decrease noise. in the lungs by congruent to 30% while increasing noise in the mediastinum by a similar amount. Without K-edge prepatient filtration, noise in the lung is minimized with Cu interdetector filter weights near 400 mg/cm(2). In the mediastinum noise is minimized with heavier interdetector filter and prepatient K-edge filter weights. Prepatient K-edge filter weights that minimize image noise in either field can increase the tube loading by factors ranging from 10 to 10(10). Systems designed with sandwich detectors using commercially available phosphors and coating weights can produce contrast-to-noise ratios (CNRs) as high as 50% of the. theoretical limit (defined as an optimized system with a totally absorbing rear detector).
引用
收藏
页码:203 / 218
页数:16
相关论文
共 35 条
[1]
Alvarez R., 1976, P SOC PHOTO-OPT INS, V96, P131
[2]
ENERGY-SELECTIVE RECONSTRUCTIONS IN X-RAY COMPUTERIZED TOMOGRAPHY [J].
ALVAREZ, RE ;
MACOVSKI, A .
PHYSICS IN MEDICINE AND BIOLOGY, 1976, 21 (05) :733-744
[3]
BREAST IMAGING - DUAL-ENERGY PROJECTION RADIOGRAPHY WITH DIGITAL RADIOGRAPHY [J].
ASAGA, T ;
CHIYASU, S ;
MASTUDA, S ;
MASTUURA, H ;
KATO, H ;
ISHIDA, M ;
KOMAKI, T .
RADIOLOGY, 1987, 164 (03) :869-870
[4]
ATTIX FH, 1986, INTRO RAD PHYSICS RA, P327
[5]
RADIOGRAPHIC MOTTLE - A COMPREHENSIVE THEORY [J].
BARNES, GT .
MEDICAL PHYSICS, 1982, 9 (05) :656-667
[6]
DETECTOR FOR DUAL-ENERGY DIGITAL RADIOGRAPHY [J].
BARNES, GT ;
SONES, RA ;
TESIC, MM ;
MORGAN, DR ;
SANDERS, JN .
RADIOLOGY, 1985, 156 (02) :537-540
[7]
A COMPARISON OF DUAL-ENERGY DIGITAL RADIOGRAPHY AND SCREEN-FILM IMAGING IN THE DETECTION OF SUBTLE INTERSTITIAL PULMONARY-DISEASE [J].
BARNES, GT ;
SABBAGH, EA ;
CHAKRABORTY, DP ;
NATH, PH ;
LUNA, RF ;
SANDERS, C ;
FRASER, RG .
INVESTIGATIVE RADIOLOGY, 1989, 24 (08) :585-591
[8]
DUAL-ENERGY MAMMOGRAPHY - A DETECTOR ANALYSIS [J].
BOONE, JM ;
SHABER, GS ;
TECOTZKY, M .
MEDICAL PHYSICS, 1990, 17 (04) :665-675
[9]
INTRAVENOUS ANGIOGRAPHY USING SCANNED PROJECTION RADIOGRAPHY - PRELIMINARY INVESTIGATION OF A NEW METHOD [J].
BRODY, WR ;
MACOVSKI, A ;
LEHMANN, L ;
DIBIANCA, FA ;
VOLZ, D ;
EDELHEIT, LS .
INVESTIGATIVE RADIOLOGY, 1980, 15 (03) :220-223
[10]
DUAL-ENERGY PROJECTION RADIOGRAPHY - INITIAL CLINICAL-EXPERIENCE [J].
BRODY, WR ;
CASSEL, DM ;
SOMMER, FG ;
LEHMANN, LA ;
MACOVSKI, A ;
ALVAREZ, RE ;
PELC, NJ ;
RIEDERER, SJ ;
HALL, AL .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1981, 137 (02) :201-205