MAGNETIC-RESONANCE ANGIOGRAPHY OF INTRAVASCULAR ENDOPROSTHESES - INVESTIGATION OF 3 DEVICES

被引:48
作者
LAISSY, JP
GRAND, C
MATOS, C
STRUYVEN, J
BERGER, JF
SCHOUMANCLAEYS, E
机构
[1] Department of Radiology, Hospital Bichat, Paris, 46, rue Henri Huchard
[2] Department of Radiology, Hospital Erasme, Brussels, 1070
关键词
ARTERIES; PERIPHERAL; GRAFTS AND PROSTHESES; STENOSIS OR OBSTRUCTION; MAGNETIC RESONANCE ANGIOGRAPHY; ARTIFACT;
D O I
10.1007/BF00338302
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose: To assess the value of magnetic resonance angiography (MRA) in the evaluation of vascular patency after intravascular endoprosthesis placement. Methods: Three different metallic stents (Wallstent, Strecker, Palmaz) were studied in vitro, and in vivo in six patients with spin-echo (SE) and gradient-echo (GRE) MR imaging. Time-of-flight, two-dimensional (2D) gadolinium-enhanced MRA was performed with GRE and flow-compensation technique, and reconstructed with a maximum-intensity projection (MIP) algorithm. MRA was compared to digital angiograms. Results: In vitro studies demonstrated that the signal intensity (SI) within the stent differed according to the device employed, the lowest SI being observed within the Palmaz stent (p = .001). There was no difference in SI or apparent diameter of the stent according to the sequence (SE vs GRE) or length of echo time (TE). In patients, the endoprostheses recorded as a well-defined area of signal void or dropout (p = 0.004), whereas vessels above and below the stent displayed high signal intensities. Conclusion: MRA does not seem as yet to be well suited for evaluating vascular patency after endoprosthesis placement, even if the Strecker and Wallstent endoprostheses provide fewer artifacts than the Palmaz stent.
引用
收藏
页码:360 / 366
页数:7
相关论文
共 20 条
[1]  
Gunther R.W., Vorwerk D., Bohndorf K., Peters I., El-Din A., Messmer B., Iliac and femoral artery stenoses and occlusions: Treatment with intravascular stents, Radiology, 172, pp. 725-730, (1989)
[2]  
Long A.L., Page P.E., Raynaud A.C., Beyssen B.M., Fiessinger J.N., Ducimetiere P., Relland J.Y., Gaux J.C., Percutaneous iliac artery stent: Angiographic long-term follow-up, Radiology, 180, pp. 771-778, (1991)
[3]  
Strecker E.P., Liermann D., Barth K.H., Wolf H.R., Freudenberg N., Berg G., Westphal M., Tsikuras P., Savin M., Schneider B., Expandable tubular stents for treatment of arterial occlusive disease: Experimental and clinical results, Radiology, 175, pp. 97-102, (1990)
[4]  
Trerotola S.O., Lund G.B., Samphilipo M.A., Magee C.A., Newman J.S., Olson J.L., Anderson J.H., Osterman F.A., Palmaz stent in the treatment of central venous stenosis: Safety and efficacy of redilation, Radiology, 190, pp. 379-385, (1994)
[5]  
Zollikofer C.L., Antonucci F., Ptyffer M., Redha F., Salomonowitz E., Stuckmann G., Largiader I., Marty A., Arterial stent placement with use of the Wallstent: Midterm results of clinical experience, Radiology, 179, pp. 449-456, (1991)
[6]  
Vorwerk D., Gunther R.W., Gehl H.B., Bohndorf K., Colorcoded image-directed Doppler sonography compared with digital subtraction angiography in the follow-up of percutaneous vascular endoprotheses, J Clin Ultrasound, 18, pp. 631-637, (1990)
[7]  
Edelman R.R., MR angiography: Present and future, AJR, 161, pp. 1-11, (1993)
[8]  
Edelman R., Mattle H.P., Atkinson D., Hoogewoud H.M., MR angiography, AJR, 154, pp. 937-946, (1990)
[9]  
Owen R.S., Carpenter J.P., Baum R.A., Perloff L.J., Cope C., Magnetic resonance imaging of angiographically occult runoff vessels in peripheral arterial occlusive disease, N Engl J Med, 326, pp. 1577-1581, (1992)
[10]  
Yucel E.K., Kaufman J.A., Geller S.C., Waltman A.C., Atherosclerotic occlusive disease of the lower extremity: Prospective evaluation with two-dimensional time-of-flight MR angiography, Radiology, 187, pp. 637-641, (1993)