ACCURACY AND REPRODUCIBILITY OF QUANTITATIVE CORONARY ARTERIOGRAPHY USING 6 AND 8 FRENCH CATHETERS WITH CINE ANGIOGRAPHIC ACQUISITION

被引:16
作者
ELLIS, SG
PINTO, IMF
MCGILLEM, MJ
DEBOE, SF
LEFREE, MT
MANCINI, GBJ
机构
[1] UNIV MICHIGAN HOSP,DEPT INTERNAL MED,DIV CARDIOL,ANN ARBOR,MI 48109
[2] UNIV MICHIGAN,SCH MED,VET ADM MED CTR,ANN ARBOR,MI 48104
来源
CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS | 1991年 / 22卷 / 01期
关键词
QUANTITATIVE ARTERIOGRAPHY; ANGIOGRAPHY;
D O I
10.1002/ccd.1810220113
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To determine the suitability of 6 French catheters for quantitative coronary arteriography, the relative accuracy and reproducibility of one type of these catheters was compared to that obtained with standard 8 French catheters in 20 stenoses. Duplicate injections with polyurethane 6 French catheters were obtained using hand and power injection technique with cineangiographic acquisition (four 6 French catheter injections total per stenosis). Measurements of both percent diameter stenosis and absolute dimensions were compared to those obtained with hand injection and cine acquisition using 8 French catheters as a "gold standard." While the reproducibility of dimension determination with the 6 French catheter was generally similar to that obtained with the 8 French catheter (0.27 +/- 0.23 mm for absolute diameter and 8.1 +/- 7.4% for percent diameter stenosis), accuracy was significantly less for the 6 French catheter for measurement of absolute dimensions. Thus, while apparently well suited for serial measurements of the same stenoses, 6 French catheters may not be as accurate in the determination of absolute artery dimensions as 8 French catheters.
引用
收藏
页码:52 / 55
页数:4
相关论文
共 18 条
  • [1] ARTERIOGRAPHIC ASSESSMENT OF CORONARY ATHEROSCLEROSIS - REVIEW OF CURRENT METHODS, THEIR LIMITATIONS, AND CLINICAL-APPLICATIONS
    BROWN, BG
    BOLSON, EL
    DODGE, HT
    [J]. ARTERIOSCLEROSIS, 1982, 2 (01): : 2 - 15
  • [2] QUANTITATIVE CORONARY ARTERIOGRAPHY - ESTIMATION OF DIMENSIONS, HEMODYNAMIC RESISTANCE, AND ATHEROMA MASS OF CORONARY-ARTERY LESIONS USING ARTERIOGRAM AND DIGITAL COMPUTATION
    BROWN, BG
    BOLSON, E
    FRIMER, M
    DODGE, HT
    [J]. CIRCULATION, 1977, 55 (02) : 329 - 337
  • [3] USE OF 5 FRENCH CATHETERS FOR CARDIAC-CATHETERIZATION AND CORONARY ANGIOGRAPHY - A CRITICAL-REVIEW
    BROWN, RIG
    MACDONALD, AC
    [J]. CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1987, 13 (03): : 214 - 217
  • [4] VARIABILITY IN ANALYSIS OF CORONARY ARTERIOGRAMS
    DEROUEN, TA
    MURRAY, JA
    OWEN, W
    [J]. CIRCULATION, 1977, 55 (02) : 324 - 328
  • [5] OPTIMAL DETECTION OF THE PROGRESSION OF CORONARY-ARTERY DISEASE - COMPARISON OF METHODS SUITABLE FOR RISK FACTOR INTERVENTION TRIALS
    ELLIS, S
    SANDERS, W
    GOULET, C
    MILLER, R
    CAIN, KC
    LESPERANCE, J
    BOURASSA, MG
    ALDERMAN, EL
    [J]. CIRCULATION, 1986, 74 (06) : 1235 - 1242
  • [6] ELLIS SG, 1987, CIRCULATION, V76, P369
  • [7] THE VALUE OF LESION CROSS-SECTIONAL AREA DETERMINED BY QUANTITATIVE CORONARY ANGIOGRAPHY IN ASSESSING THE PHYSIOLOGIC SIGNIFICANCE OF PROXIMAL LEFT ANTERIOR DESCENDING CORONARY ARTERIAL STENOSES
    HARRISON, DG
    WHITE, CW
    HIRATZKA, LF
    DOTY, DB
    BARNES, DH
    EASTHAM, CL
    MARCUS, ML
    [J]. CIRCULATION, 1984, 69 (06) : 1111 - 1119
  • [8] RETHROMBOSIS AFTER REPERFUSION WITH STREPTOKINASE - IMPORTANCE OF GEOMETRY OF RESIDUAL LESIONS
    HARRISON, DG
    FERGUSON, DW
    COLLINS, SM
    SKORTON, DJ
    ERICKSEN, EE
    KIOSCHOS, JM
    MARCUS, ML
    WHITE, CW
    [J]. CIRCULATION, 1984, 69 (05) : 991 - 999
  • [9] KLINKE WP, 1989, CLIN RES, V37, pA95
  • [10] AUTOMATED QUANTITATIVE CORONARY ARTERIOGRAPHY - MORPHOLOGICAL AND PHYSIOLOGICAL VALIDATION IN VIVO OF A RAPID DIGITAL ANGIOGRAPHIC METHOD
    MANCINI, GBJ
    SIMON, SB
    MCGILLEM, MJ
    LEFREE, MT
    FRIEDMAN, HZ
    VOGEL, RA
    [J]. CIRCULATION, 1987, 75 (02) : 452 - 460