THE SINUS NODE INHIBITOR UL-FS-49 LACKS SIGNIFICANT INOTROPIC EFFECT

被引:17
作者
CHEN, ZY
SLINKER, BK
机构
[1] Cardiology Unit, Department of Medicine, University of Vermont, Burlington, VT
关键词
INOTROPIC STATE; HEMODYNAMICS; VENTRICULAR FUNCTION; MULTIPLE REGRESSION MODELING;
D O I
10.1097/00005344-199202000-00015
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
UL-FS 49 is a sinus node inhibitor that has been reported to reduce heart rate and may be useful in improving myocardial oxygen supply vs. demand. However, previous studies performed in a variety of preparations have produced mixed results regarding the independent inotropic effect of UL-FS 49. To determine whether UL-FS 49 has an inotropic effect, we measured both steady-state hemodynamic responses and transient hemodynamic responses to random preload and afterload changes, both with and without UL-FS 49. We found that under steady-state conditions, the effect of UL-FS 49 is so small that it would be of doubtful physiologic significance: a 39% increase in stroke volume (p = 0.007) and 7% increase in peak positive dP/dt (p = 0.051), in the presence of no statistically significant differences in end-diastolic pressure, end-diastolic volume, peak systolic pressure, end-systolic pressure, or heart rate. The more powerful multiple linear regression modeling of hemodynamic transient sequences resulting from random preload and afterload changes showed that UL-FS 49 is without a statistically significant direct effect on left ventricular function. We conclude that UL-FS 49 has no physiologically important direct effect on left ventricular pump function.
引用
收藏
页码:264 / 271
页数:8
相关论文
共 30 条
  • [1] MAXIMAL NEGATIVE DP-DT AS AN INDICATOR OF END OF SYSTOLE
    ABEL, FL
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY, 1981, 240 (04): : H676 - H679
  • [2] CONTINUOUS MEASUREMENT OF LEFT-VENTRICULAR VOLUME IN ANIMALS AND HUMANS BY CONDUCTANCE CATHETER
    BAAN, J
    VANDERVELDE, ET
    DEBRUIN, HG
    SMEENK, GJ
    KOOPS, J
    VANDIJK, AD
    TEMMERMAN, D
    SENDEN, J
    BUIS, B
    [J]. CIRCULATION, 1984, 70 (05) : 812 - 823
  • [3] LEFT-VENTRICULAR VOLUME MEASUREMENT BY CONDUCTANCE CATHETER IN INTACT DOGS - PARALLEL CONDUCTANCE VOLUME DEPENDS ON LEFT-VENTRICULAR SIZE
    BOLTWOOD, CM
    APPLEYARD, RF
    GLANTZ, SA
    [J]. CIRCULATION, 1989, 80 (05) : 1360 - 1377
  • [4] DAMMGEN JW, 1985, J CARDIOVASC PHARM, V7, P71
  • [5] DIXON WJ, 1988, BMDP STATISTICAL SOF, V1, P147
  • [6] DOERR T, 1990, N-S ARCH PHARMACOL, V341, P331
  • [7] FRANKE H, 1987, European Heart Journal, V8, P91
  • [8] VOLUME CONDUNCTANCE CATHETER
    GLANTZ, SA
    BOLTWOOD, CM
    APPLEYARD, RF
    APPLEGATE, RJ
    CHENG, CP
    LITTLE, WC
    [J]. CIRCULATION, 1990, 81 (06) : 2028 - 2028
  • [9] GLANTZ SA, 1990, PRIMER APPLIED REGRE, P239
  • [10] GUNST RF, 1980, REGRESION ANAL ITS A, P234