The Ventritex(R) Cadence(R) Model V-100 Tiered Therapy Defibrillator is a third generation antitachyarrhythmia device currently completing clinical trials in the United States. The implantable pulse generator is capable of high energy defibrillation, low energy cardioversion, as well as antitachycardia and bradycardia pacing. In addition, this microprocessor controlled device can deliver monophasic or biphasic defibrillation/cardioversion shocks, is noncommitted to deliver shock therapy after initiating charging for defibrillation or cardioversion therapy, and can store electrograms of spontaneous tachyarrhythmia episodes. These expanded device capabilities should improve therapy efficacy and patient management, and represent a major advance in the treatment of patients with ventricular tachyarrhythmias.
引用
收藏
页码:211 / 223
页数:13
相关论文
共 12 条
[1]  
Winkle RA., Mead RH, Ruder MA, Et al., Long‐term outcome with the automatic implantable cardioverter‐defibrillator, J Am Coll Cardiol, 13, pp. 1353-1361, (1989)
[2]  
Thomas AC., Moser SA., Smutka ML, Et al., Implantable defibrillation: Eight yours clinical experience, PACE, 11, pp. 2053-2058, (1988)
[3]  
Winkle RA., Fain ES., Mead RH, Et al., Clinical feasibility of an automatic combined antilachycardia device, Circulation, 78, pp. 2-220, (1988)
[4]  
Winkle RA, Mead RH., Ruder MA, Et al., Improved low energy defibrillation efficacy in man with the use of a truncated exponential waveform, Am Heart J, 117, pp. 122-127, (1989)
[5]  
Bardy GH., Ivey TD, Allen MD, Et al., A prospective randomized evaluation of biphasic versus monophasic waveform pulses on defibrillation efficacy in humans, J Am Cull Cardinl, 14, pp. 728-733, (1989)
[6]  
Chapman PD., Vetter JW, Souza JJ, Et al., Comparative efficacy of monophasic and biphasic truncated exponential shocks for nonthoracotomy internal defibrillation in dogs, J Am Coll Cardiol, 12, pp. 739-745, (1988)
[7]  
Perlman R, Hook B., Marchlinski F, Et al., Rate dependent changes in bipolar pacing threshold in a combined anti‐tachycardia pacemaker/defibrillator, PACE, 13, (1990)
[8]  
Winkle RA, Fain ES., Sweeney MB, Et al., Survival in patients with ventricular tachyarrhythmias treated with programmable tiered therapy implantable defibrillators, J Am Coll Cardiol, 19, (1992)
[9]  
Winkle RA, Fain ES, Hardage ML., Et al., The value and usage of programmability in tiered therapy defibrillator, J Am Coll Cardiol, 19, (1992)
[10]  
Hook BG, Marchlinski FE, Value of ventricular electrogram recordings in Ihe diagnosis of arrhythmias precipitating electrical device shock therapy, 5 Am Coll Cardiol, 17, pp. 985-990, (1991)