SIMULTANEOUS ENZYMATIC DETERMINATION OF GLUCOSE AND ASCORBIC-ACID USING FLOW-INJECTION AMPEROMETRY

被引:17
作者
MATUSZEWSKI, W
TROJANOWICZ, M
ILCHEVA, L
机构
[1] UNIV WARSAW,DEPT CHEM,PASTEURA 1,PL-02093 WARSAW,POLAND
[2] HIGHER INST CHEM TECHNOL,DEPT ANALYT CHEM,BU-1156 SOFIA,BULGARIA
关键词
D O I
10.1002/elan.1140020211
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A flow‐injection procedure involving the glucose oxidase‐catalyzed oxidation of glucose and direct am‐perometric determination of ascorbic acid was developed for simultaneous determination of the two compounds. Experimental conditions of measurement, including the sample volume, flow rate, and delay coil length, were optimized to obtain satisfactory resolution for the two flow‐injection peaks. The principle of analytical interpretation of the obtained signal is presented, and the applicability of the determination of glucose and ascorbic acid in fresh fruit juices samples is illustrated. Copyright © 1990 VCH Publishers, Inc.
引用
收藏
页码:147 / 153
页数:7
相关论文
共 15 条
[1]   ENZYMATIC DETERMINATION OF GLUCOSE IN A FLOW SYSTEM BY CATALYTIC-OXIDATION OF THE NICOTINAMIDE COENZYME AT A MODIFIED ELECTRODE [J].
APPELQVIST, R ;
MARKOVARGA, G ;
GORTON, L ;
TORSTENSSON, A ;
JOHANSSON, G .
ANALYTICA CHIMICA ACTA, 1985, 169 (MAR) :237-247
[2]   EVALUATION OF KEL-F-GRAPHITE ELECTRODES AS DETECTORS FOR CONTINUOUS-FLOW SYSTEMS [J].
CHESNEY, DJ ;
ANDERSON, JL ;
WEISSHAAR, DE ;
TALLMAN, DE .
ANALYTICA CHIMICA ACTA, 1981, 124 (02) :321-331
[3]  
HAHN Y, 1988, Archives of Pharmacal Research (Seoul), V11, P56, DOI 10.1007/BF02884769
[4]  
IKEDA S, 1984, CHEM LETT, V6, P873
[5]   VOLTAMMETRIC AMPEROMETRIC DETECTION FOR FLOW-INJECTION SYSTEMS [J].
LUNTE, CE ;
WONG, SW ;
RIDGWAY, TH ;
HEINEMAN, WR ;
CHAN, KW .
ANALYTICA CHIMICA ACTA, 1986, 188 :263-267
[6]  
MASOOM M, 1984, ANAL CHIM ACTA, V166, P111
[7]   SIMULTANEOUS DETERMINATION OF GLUCOSE, FRUCTOSE, AND SUCROSE IN MIXTURES BY AMPEROMETRIC FLOW-INJECTION ANALYSIS WITH IMMOBILIZED ENZYME REACTORS [J].
MATSUMOTO, K ;
KAMIKADO, H ;
MATSUBARA, H ;
OSAJIMA, Y .
ANALYTICAL CHEMISTRY, 1988, 60 (02) :147-151
[8]   GRAPHITE PASTE-BASED ENZYMATIC GLUCOSE ELECTRODE FOR FLOW-INJECTION ANALYSIS [J].
MATUSZEWSKI, W ;
TROJANOWICZ, M .
ANALYST, 1988, 113 (05) :735-738
[9]  
MATUSZEWSKI W, 1988, ELECTROFINNANALYSIS
[10]   GLUCOSE ENZYME ELECTRODE WITH EXTENDED LINEARITY - APPLICATION TO UNDILUTED BLOOD MEASUREMENTS [J].
MULLEN, WH ;
KEEDY, FH ;
CHURCHOUSE, SJ ;
VADGAMA, PM .
ANALYTICA CHIMICA ACTA, 1986, 183 :59-66