DIELECTRIC PROPERTY MEASUREMENTS OF MATERIALS USING THE CAVITY TECHNIQUE

被引:12
作者
BAYSAR, A
KUESTER, JL
机构
[1] Department of Chemical, Bio and Materials Engineering, Arizona State University, Tempe
关键词
D O I
10.1109/22.168772
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A cavity technique based on frequency shift was used to measure dielectric properties (dielectric constant and loss factor) of some particulate materials as a function of temperature. The materials studied were alumina, cobalt/alumina, dolomite and sand. The properties were measured at various points between room temperature and 610-degrees-C in the frequency range of 925-995 MHz. The dielectric constant and loss factor of all samples, except the cobalt/alumina catalyst sample, were approximately constant with temperature. The dielectric constant and loss factor of the cobalt/alumina sample exhibited a noticeable increase with temperature.
引用
收藏
页码:2108 / 2110
页数:3
相关论文
共 7 条
[1]  
BAYSAR A, 1991, J MICROWAVE POWER EE, V26, P145
[2]  
BAYSAR A, 1992, THESIS ARIZONA STATE
[3]   DIELECTRIC MEASUREMENTS OF SHEET MATERIALS [J].
BHARTIA, P ;
HAMID, MAK .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1973, IM22 (01) :94-95
[4]  
KUESTER JL, 1982, DOECS40202T6 US DEP
[5]   MICROWAVE Q-MEASUREMENTS IN THE PRESENCE OF SERIES LOSSES [J].
MALTER, L ;
BREWER, GR .
JOURNAL OF APPLIED PHYSICS, 1949, 20 (10) :918-925
[6]  
Sucher M., 1963, HDB MICROWAVE MEASUR, V2
[7]  
WESTPHAL WB, 1963, MIT182 LAB INS RES T