IMPROVED SCANNING TUNNELING MICROSCOPE FEEDBACK PERFORMANCE BY MEANS OF SEPARATE ACTUATORS

被引:4
作者
TAPSON, J [1 ]
GREENE, JR [1 ]
BALL, A [1 ]
机构
[1] UNIV CAPE TOWN,DEPT MAT ENGN,RONDEBOSCH 7700,SOUTH AFRICA
来源
JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B | 1994年 / 12卷 / 03期
关键词
D O I
10.1116/1.587257
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Scanning tunneling microscopes (STMs) are usually operated in current-feedback mode when scanning over wide areas or rough surfaces. The speed of image acquisition is determined by the scanning rate, which (in this mode) is limited by the bandwidth of the feedback control loop. The control loop bandwidth is usually restricted to frequencies lower than the lowest mechanical resonant frequency (f(r)) of the STM scanner and tip. This resonant frequency is typically in the range 5-15 kHz and is generally ascribed to mechanical resonance of the piezoelectric scanner tube or scanner tripod. In this article we describe some measured sources of mechanical resonance in STMs, and present a design which eliminates the need to control the scanner at high frequencies. We have established that the lowest mechanical resonance mode may be ascribed to the base mounting structure (in addition to the scanning actuator), depending on the specific design. The complex origins of this mode prevent the use of conventional control techniques at frequencies above f(r). We have developed an STM design in which a separate feedback actuator is used to modulate the z position of the sample, independently to the scanning (x and y) actuator. The effective resonance frequency of this actuator is extremely high (in excess of 100 kHz) and the control bandwidth is correspondingly improved.
引用
收藏
页码:1662 / 1664
页数:3
相关论文
共 9 条
[1]  
BINNIG G, 1986, IBM J RES DEV, V30, P355
[2]   SINGLE-TUBE 3-DIMENSIONAL SCANNER FOR SCANNING TUNNELING MICROSCOPY [J].
BINNIG, G ;
SMITH, DPE .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1986, 57 (08) :1688-1689
[3]   INSITU TESTING AND CALIBRATION OF TUBE PIEZOELECTRIC SCANNERS [J].
CHEN, CJ .
ULTRAMICROSCOPY, 1992, 42 :1653-1658
[4]   CONTROL-SYSTEMS FOR SCANNING TUNNELING MICROSCOPES WITH TUBE SCANNERS [J].
DILELLA, DP ;
WANDASS, JH ;
COLTON, RJ ;
MARRIAN, CRK .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1989, 60 (06) :997-1002
[5]   SOME DESIGN CRITERIA IN SCANNING TUNNELING MICROSCOPY [J].
POHL, DW .
IBM JOURNAL OF RESEARCH AND DEVELOPMENT, 1986, 30 (04) :417-427
[6]  
QUATE CF, 1987, REV SCI INSTRUM, V58, P2004
[7]   IMAGING BIOLOGICAL MACROMOLECULES BY STM - QUANTITATIVE INTERPRETATION OF TOPOGRAPHS [J].
STEMMER, A ;
ENGEL, A .
ULTRAMICROSCOPY, 1990, 34 (03) :129-140
[8]   A VERSATILE MICROWAVE-FREQUENCY-COMPATIBLE SCANNING TUNNELING MICROSCOPE [J].
STRANICK, SJ ;
WEISS, PS .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1993, 64 (05) :1232-1234
[9]   DYNAMICS OF PIEZOELECTRIC TUBE SCANNERS FOR SCANNING PROBE MICROSCOPY [J].
TAYLOR, ME .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1993, 64 (01) :154-158