COMBINED HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC CONTINUOUS-FLOW FAST ATOM BOMBARDMENT MASS-SPECTROMETRIC ANALYSIS OF ACYLCOENZYME-A COMPOUNDS

被引:23
作者
NORWOOD, DL
BUS, CA
MILLINGTON, DS
机构
[1] Division of Pediatric Genetics and Metabolism, Duke University Medical Center, Durham, NC 27710
来源
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS | 1990年 / 527卷 / 02期
关键词
D O I
10.1016/S0378-4347(00)82113-1
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A high-performance liquid chromatographic method for the analysis of coenzyme A thioesters which employs continuous-flow fast atom bombardment mass spectrometric detection is presented. The chromatographic system utilizes gradient elution with reversed-phase conditions using ammonium acetate-acetonitrile from both standard analytical (3.9 mm I.D.) and microbore (1 mm I.D.) columns. Applications to coenzyme A thioesters of various acyl group chain length (C2-C18) and functionality (-COOH, -OH, -CC-) are described. The system is also applied to an in vitro enzyme reaction (crotonase) to directly follow the disappearance of substrate and appearance of product. The mass spectrometry of coenzyme A thioesters, their chromatographic behavior, system stability, and sensitivity of detection are discussed. © 1990.
引用
收藏
页码:289 / 301
页数:13
相关论文
共 22 条
[1]   ANALYSIS AND PURIFICATION OF ACYL COENZYME-A THIOESTERS BY REVERSED-PHASE ION-PAIR LIQUID-CHROMATOGRAPHY [J].
BAKER, FC ;
SCHOOLEY, DA .
ANALYTICAL BIOCHEMISTRY, 1979, 94 (02) :417-424
[2]  
BARBER M, 1982, ANAL CHEM, V54, pA645
[3]  
BARBER M, 1981, J CHEM SOC CHEM COMM, V7, P325
[4]   DETERMINATION OF KM AND VMAX FOR TRYPTIC PEPTIDE HYDROLYSIS USING FAST-ATOM-BOMBARDMENT MASS-SPECTROMETRY [J].
CAPRIOLI, RM ;
SMITH, L .
ANALYTICAL CHEMISTRY, 1986, 58 (06) :1080-1083
[5]   CONTINUOUS-FLOW SAMPLE PROBE FOR FAST-ATOM-BOMBARDMENT MASS-SPECTROMETRY [J].
CAPRIOLI, RM ;
FAN, T ;
COTTRELL, JS .
ANALYTICAL CHEMISTRY, 1986, 58 (14) :2949-2954
[6]  
Chalmers RA, 1982, ORGANIC ACIDS MAN
[7]   RELATIONSHIP BETWEEN UNUSUAL HEPATIC ACYL COENZYME-A PROFILES AND THE PATHOGENESIS OF REYE SYNDROME [J].
CORKEY, BE ;
HALE, DE ;
GLENNON, MC ;
KELLEY, RI ;
COATES, PM ;
KILPATRICK, L ;
STANLEY, CA .
JOURNAL OF CLINICAL INVESTIGATION, 1988, 82 (03) :782-788
[8]   ASSAY OF SHORT-CHAIN ACYL COENZYME-A INTERMEDIATES IN TISSUE-EXTRACTS BY HIGH-PRESSURE LIQUID-CHROMATOGRAPHY [J].
CORKEY, BE ;
BRANDT, M ;
WILLIAMS, RJ ;
WILLIAMSON, JR .
ANALYTICAL BIOCHEMISTRY, 1981, 118 (01) :30-41
[9]   THE ANALYSIS OF ACYL-COENZYME A DERIVATIVES BY REVERSE-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
DEBUYSERE, MS ;
OLSON, MS .
ANALYTICAL BIOCHEMISTRY, 1983, 133 (02) :373-379
[10]   DETERMINATION OF SHORT-CHAIN ACYL-COENZYME A-ESTERS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
HOSOKAWA, Y ;
SHIMOMURA, Y ;
HARRIS, RA ;
OZAWA, T .
ANALYTICAL BIOCHEMISTRY, 1986, 153 (01) :45-49