INVESTIGATIONS OF PLATINIZED AND RHODINIZED CARBON ELECTRODES FOR USE IN GLUCOSE SENSORS

被引:46
作者
WHITE, SF
TURNER, APF
SCHMID, RD
BILITEWSKI, U
BRADLEY, J
机构
[1] CRANFIELD UNIV,CRANFIELD BIOTECHNOL CTR,CRANFIELD MK43 0AL,BEDS,ENGLAND
[2] GESELL BIOTECHNOL FORSCH MBH,W-3300 BRAUNSCHWEIG,GERMANY
关键词
GLUCOSE; BIOSENSORS; METALLIZATION; RHODIUM;
D O I
10.1002/elan.1140060803
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Graphite electrodes were modified by the electrodeposition of either platinum or rhodium, using cyclic voltammetry. Following only brief periods nf treatment, plantinized carbon electrodes were able to directly oxidize glucose at a potential of +350 mV (vs. Ag/AgCl). By narrowing both the potential range of deposition (-450 to -500 mV) and cycling period (50 seconds at a scan rate of 10 mV s(-1)), the effects of direct glucose oxidation could be significantly: reduced. Detection of H2O2 at +400 mV was possible; glucose enzyme electrodes were constructed, with glucose oxidase immobilized in hydroxyethylcellulose and operated at this potential. These sensors had a linear range of 0.1 to 25 mM glucose and a slope of 8 nA/mM. Other electrodes were prepared by the electrodeposition of rhodium. These base electrodes proved to be insensitive to glucose and produced higher currents (compared to low platinum electrodes) to H2O2. Glucose sensors were constructed using rhodinized electrodes. Again operating at +400 mV, these sensors had a linear range from 0.1 to 20 mM and a slope of 21 nA/mM glucose.
引用
收藏
页码:625 / 632
页数:8
相关论文
共 21 条
[1]  
BENNETTO HP, 1987, INT ANAL, V8, P22
[2]  
BENNETTO HP, 1988, INT IND BIOTECHNOL, V8, P5
[3]   IMMOBILIZATION OF GLUCOSE-OXIDASE IN A POLY [VINYL ALCOHOL] MATRIX ON PLATINIZED GRAPHITE-ELECTRODES BY GAMMA-IRRADIATION [J].
GALIATSATOS, C ;
IKARIYAMA, Y ;
MARK, JE ;
HEINEMAN, WR .
BIOSENSORS & BIOELECTRONICS, 1990, 5 (01) :47-61
[4]  
Giner J, 1969, P ARTIFICIAL HEART P, P839
[5]   AN INVESTIGATION OF THE INFLUENCES OF THE BACKGROUND MATERIAL AND LAYER THICKNESS OF SPUTTERED PALLADIUM GOLD ON CARBON ELECTRODES FOR THE AMPEROMETRIC DETERMINATION OF HYDROGEN-PEROXIDE [J].
GORTON, L ;
SVENSSON, T .
JOURNAL OF MOLECULAR CATALYSIS, 1986, 38 (1-2) :49-60
[6]   SELECTIVE DETECTION IN FLOW-ANALYSIS BASED ON THE COMBINATION OF IMMOBILIZED ENZYMES AND CHEMICALLY MODIFIED ELECTRODES [J].
GORTON, L ;
CSOREGI, E ;
DOMINGUEZ, E ;
EMNEUS, J ;
JONSSONPETTERSSON, G ;
MARKOVARGA, G ;
PERSSON, B .
ANALYTICA CHIMICA ACTA, 1991, 250 (01) :203-248
[7]   PLATINUM-DISPERSED NAFION FILM MODIFIED GLASSY-CARBON AS AN ELECTROCATALYTIC SURFACE FOR AN AMPEROMETRIC GLUCOSE ENZYME ELECTRODE [J].
GUNASINGHAM, H ;
TAN, CB .
ANALYST, 1989, 114 (06) :695-698
[8]   GLUCOSE ENZYME ELECTRODE PREPARATION BY THE CODEPOSITION OF PLATINUM AND GLUCOSE-OXIDASE ONTO GLASSY-CARBON [J].
GUNASINGHAM, H ;
TAN, CB .
ELECTROANALYSIS, 1989, 1 (03) :223-227
[9]  
ITAVA K, 1986, J ELECTROANAL CHEM, V208, P373
[10]  
JONSSON G, 1987, ANAL LETT, V20, P839