HYDROXYLAPATITE POLY(L-LACTIDE) COMPOSITES - AN ANIMAL STUDY ON PUSH-OUT STRENGTHS AND INTERFACE HISTOLOGY

被引:113
作者
VERHEYEN, CCPM [1 ]
DEWIJN, JR [1 ]
VANBLITTERSWIJK, CA [1 ]
DEGROOT, K [1 ]
ROZING, PM [1 ]
机构
[1] LEIDEN UNIV,SCH MED,DIV ORTHOPAED SURG,BIOMAT RES GRP,2333 AA LEIDEN,NETHERLANDS
来源
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH | 1993年 / 27卷 / 04期
关键词
D O I
10.1002/jbm.820270404
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In the development of new materials for resorbable systems for bone fixation and replacement, composites of hydroxylapatite and poly (L-lactide) (HA/PLLA) were tested. In a transcortical implantation model in goats the interactions at the bone-implant interface were studied with post-operative intervals up to 1 year. Push-out testing of the implants indicated that PLLA reinforced with 50 wt% hydroxylapatite or PLLA plasma-sprayed with a hydroxylapatite coating of 50 mum thickness increases interfacial shear strength at 3 months of implantation when compared to unfilled poly(L-lactide) (P < .01). Scanning electron microscopy showed that the failure mode was predominantly at the coating-implant interface. Implantation periods longer than 3 months did not result in a significant increase in push-out strength because of the resorbing PLLA matrix. In support of the above findings there was histological evidence, on a light microscopical level, of increased bone contact at the interface for the composites, HA incorporated in or coated on PLLA, compared to unfilled poly(L-lactide).
引用
收藏
页码:433 / 444
页数:12
相关论文
共 29 条
[1]  
Bajpai P., 1983, BIOMATERIALS RECONST, P312, DOI 10.1016/B978-0-12-802792-9.00001-X
[2]   PUSH-OUT TESTS [J].
BLACK, J .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1989, 23 (11) :1243-1245
[3]   RESORBABLE POLY(L-LACTIDE) PLATES AND SCREWS FOR THE FIXATION OF ZYGOMATIC FRACTURES [J].
BOS, RRM ;
BOERING, G ;
ROZEMA, FR ;
LEENSLAG, JW .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1987, 45 (09) :751-753
[4]   FOREIGN-BODY REACTIONS TO FRACTURE FIXATION IMPLANTS OF BIODEGRADABLE SYNTHETIC-POLYMERS [J].
BOSTMAN, O ;
HIRVENSALO, E ;
MAKINEN, J ;
ROKKANEN, P .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1990, 72 (04) :592-596
[5]   OSTEOLYTIC CHANGES ACCOMPANYING DEGRADATION OF ABSORBABLE FRACTURE FIXATION IMPLANTS [J].
BOSTMAN, OM .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1991, 73 (04) :679-682
[6]  
COOK SD, 1988, CLIN ORTHOP RELAT R, V230, P303
[7]   A FINITE-ELEMENT ANALYSIS OF THE PUSH-OUT TEST - INFLUENCE OF TEST CONDITIONS [J].
DHERT, WJA ;
VERHEYEN, CCPM ;
BRAAK, LH ;
DEWIJN, JR ;
KLEIN, CPAT ;
DEGROOT, K ;
ROZING, PM .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1992, 26 (01) :119-130
[8]   A MECHANICAL INVESTIGATION OF FLUORAPATITE, MAGNESIUMWHITLOCKITE, AND HYDROXYLAPATITE PLASMA-SPRAYED COATINGS IN GOATS [J].
DHERT, WJA ;
KLEIN, CPAT ;
WOLKE, JGC ;
VANDERVELDE, EA ;
DEGROOT, K ;
ROZING, PM .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1991, 25 (10) :1183-1200
[9]  
EITENMULLER J, 1988, 3RD WORLD BIOM C KYO
[10]  
FRAZZA E J, 1971, Journal of Biomedical Materials Research Biomedical Materials Symposium, V1, P43