3-STAGE MP ACCELERATOR UPGRADE PROGRAM AT BROOKHAVEN-NATIONAL-LABORATORY

被引:4
作者
THIEBERGER, P [1 ]
LINDGREN, R [1 ]
MCKEOWN, M [1 ]
ROBINSON, T [1 ]
WEGNER, HE [1 ]
机构
[1] BROOKHAVEN NATL LAB,UPTON,NY 11973
关键词
D O I
10.1109/TNS.1977.4328855
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
引用
收藏
页码:1081 / 1083
页数:3
相关论文
共 9 条
[1]  
BENJAMIN JA, IEEE T NUCL SCI, V18
[2]   NEW DEVELOPMENTS IN BEAM TRANSPORT THROUGH TANDEM ACCELERATORS [J].
LARSON, JD .
NUCLEAR INSTRUMENTS & METHODS, 1974, 122 (1-2) :53-63
[3]   UNGRIDDED ELECTROSTATIC MIRROR [J].
LARSON, JD ;
BENJAMIN, JA .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1968, 39 (02) :272-&
[4]  
LETOURNEL M, COMMUNICATION
[5]   CLOSE TO UNIVERSAL NEGATIVE-ION SOURCE [J].
MIDDLETO.R ;
ADAMS, CT .
NUCLEAR INSTRUMENTS & METHODS, 1974, 118 (02) :329-336
[6]   UNIVERSITY-OF-ROCHESTER MP TANDEM UPGRADING PROGRAM [J].
PURSER, KH ;
GOVE, HE ;
LUND, TS ;
HYDER, HRMK .
NUCLEAR INSTRUMENTS & METHODS, 1974, 122 (1-2) :159-177
[7]   USE OF DUAL FOIL STRIPPING AT BROOKHAVEN TANDEM ACCELERATOR FACILITY FOR IMPROVED HEAVY-ION PERFORMANCE [J].
THIEBERGER, P ;
WEGNER, HE ;
MCKEOWN, M ;
MANNI, M ;
FEIGENBAUM, I .
NUCLEAR INSTRUMENTS & METHODS, 1974, 122 (03) :291-293
[8]   BROOKHAVEN-NATIONAL-LABORATORY 3-STAGE MP TANDEM VANDEGRAAFF FACILITY [J].
THIEBERGER, P ;
WEGNER, HE .
NUCLEAR INSTRUMENTS & METHODS, 1974, 122 (1-2) :205-212
[9]   TEST OF HEAVY-ION GAS-FOIL STRIPPING FOR IMPROVED FOIL LIFETIME IN TANDEM VANDEGRAAFF ACCELERATORS [J].
THIEBERGER, P ;
WEGNER, HE .
NUCLEAR INSTRUMENTS & METHODS, 1975, 126 (02) :231-233