VALIDATION OF 1-MM AND 2-MM TRANSIT-TIME ULTRASOUND FLOW PROBES ON MESENTERIC-ARTERY AND AORTA OF RATS

被引:42
作者
DALMEIDA, MS
GAUDIN, C
LEBREC, D
机构
来源
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY | 1995年 / 268卷 / 03期
关键词
BLOOD FLOW MEASUREMENT; PERIVASCULAR FLOW PROBES; PERFUSION CIRCUIT;
D O I
10.1152/ajpheart.1995.268.3.H1368
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The aim of this investigation was to validate and calibrate the 1- and 2-mm transit-time ultrasound, perivascular flow probes on the superior mesenteric artery and aorta of the rat by using an in vivo and in situ calibration system. The baseline blood flows measured by the flowmeter zero-flow function and the true-zero flow measurement, after complete occlusion of the vessels, were not different. The probes were then calibrated, in situ, by timed-volume measurements with a blood/saline pump-perfused circuit. The relationship between measured flow and true flow was linear for both probes. The slope of the 1-mm probe data was not significantly different from the line of identity, whereas the 2-mm probe data slightly overestimated the true flow (slope = 1.2, y-intercept = -3.2 ml/min). The slope of the middle region of the 2-mm probe data, however, was not significantly different from the line of identity, suggesting that the 2-mm probe has a window of accuracy over this range of flows. Progressive elimination of the low and high data points varying the most from the line of identity and reanalysis of the data revealed that the window of accuracy for the 2-mm probe, under our experimental conditions, was between 10.4 and 45.1 ml/min.
引用
收藏
页码:H1368 / H1372
页数:5
相关论文
共 15 条
  • [1] DROST CJ, 1979, 7TH P N ENGL NE BIOE, P220
  • [2] BLOOD-FLOW TO HINDQUARTERS OF STEERS MEASURED BY TRANSIT-TIME ULTRASOUND AND INDICATOR DILUTION
    EISEMANN, JH
    HUNTINGTON, GB
    FERRELL, CL
    [J]. JOURNAL OF DAIRY SCIENCE, 1987, 70 (07) : 1385 - 1390
  • [3] GOREWIT RC, 1984, J DAIRY SCI S, V67, P159
  • [4] PROSTAGLANDINS DO NOT MEDIATE IMPAIRED AUTOREGULATION OR INCREASED RENIN SECRETION IN REMNANT RAT KIDNEYS
    GRIFFIN, KA
    BIDANI, AK
    PICKEN, M
    ELLIS, VR
    CHURCHILL, PC
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY, 1992, 263 (06): : F1057 - F1062
  • [5] ROLE OF ENDOTHELIUM-DERIVED NITRIC-OXIDE IN HEMODYNAMIC ADAPTATIONS AFTER GRADED RENAL MASS REDUCTION
    GRIFFIN, KA
    BIDANI, AK
    OUYANG, J
    ELLIS, V
    CHURCHILL, M
    CHURCHILL, PC
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY, 1993, 264 (06): : R1254 - R1259
  • [6] HARTMAN J, 1985, PHARMACOLOGIST, V27, P217
  • [7] NITRIC OXIDE-DEPENDENT AND OXIDE-INDEPENDENT HYPEREMIA DUE TO CALCITONIN-GENE-RELATED PEPTIDE IN THE RAT STOMACH
    HOLZER, P
    LIPPE, IT
    JOCIC, M
    WACHTER, C
    ERB, R
    HEINEMANN, A
    [J]. BRITISH JOURNAL OF PHARMACOLOGY, 1993, 110 (01) : 404 - 410
  • [8] ANGIOTENSIN-II/PROSTAGLANDIN-I(2) INTERACTIONS IN SPONTANEOUSLY HYPERTENSIVE RATS
    JACKSON, EK
    HERZER, WA
    [J]. HYPERTENSION, 1993, 22 (05) : 688 - 698
  • [9] KANTER DE, 1994, TRANSIT TIMES, P2
  • [10] MYERS SI, 1992, SURGERY, V112, P347