LONG-TERM CONTRACEPTION WITH THE LEVONORGESTREL 20 MCG/DAY (LNG 20) AND THE COPPER-T 380AG INTRAUTERINE-DEVICES - A 5-YEAR RANDOMIZED STUDY

被引:148
作者
SIVIN, I
ELMAHGOUB, S
MCCARTHY, T
MISHELL, DR
SHOUPE, D
ALVAREZ, F
BRACHE, V
JIMENEZ, E
DIAZ, J
FAUNDES, A
DIAZ, MM
COUTINHO, E
MATTOS, CER
DIAZ, S
PAVEZ, M
STERN, J
机构
[1] AIN SHAMS UNIV, DEPT OBSTET & GYNECOL, CAIRO, EGYPT
[2] NATL UNIV SINGAPORE, DEPT OBSTET & GYNECOL, SINGAPORE, SINGAPORE
[3] UNIV SO CALIF, SCH MED, DEPT OBSTET & GYNECOL, LOS ANGELES, CA 90033 USA
[4] CTR INVEST & SERV REPROD HUMANA & ANTICONCEPC, PROFAMILIA, SANTO DOMINGO, DOMINICAN REP
[5] CTR PESQUISAS & CONTROLE DOENCAS MATERNO INFANTIS, CAMPINAS, SP, BRAZIL
[6] UNIV FED BAHIA, FAC MED MATERNIDADE CLIMERIO OLIVEIRA, SALVADOR, BA, BRAZIL
[7] INST CHILENO MED REPROD, SANTIAGO, CHILE
基金
美国安德鲁·梅隆基金会;
关键词
D O I
10.1016/0010-7824(90)90046-X
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
An intrauterine device, releasing approximately 20 μg/day of levonorgestrel (LNg 20), used by 1124 women, was studied in a randomized trial of five years duration in comparison with the Copper T, model TCu 380Ag, in 1121 women. At five years, the gross cumulative pregnancy rate of 1.1±0.5 per 100 among users of the LNg 20 devices was not significantly different from the rate of 1.4±0.4 per 100 experienced by users of the Copper T 380Ag. The steroid-releasing IUD had significantly higher termination rates for expulsion and amenorrhea, a significantly lower termination rate for other menstrual problems and pain, and a lower continuation rate. The five-year continuation rate among women using the TCu 380Ag was 40.6 per 100 as compared with that of 33.0 per 100 among women randomized to the LNg 20 device (P < .001). Terminations attributed to amenorrhea with the LNg device primarily account for differences in continuation. These two Intrauterlne devices are the most effective long-term, reversible IUDs yet reported in the literature. No other contraceptive methods have exhibited such low long-term pregnancy rates in randomized comparative trials. © 1990.
引用
收藏
页码:361 / 378
页数:18
相关论文
共 18 条
[1]   RECOVERY OF FERTILITY AFTER USE OF THE LEVONORGESTREL 20 MCG/D OR COPPER T-380 AG INTRAUTERINE-DEVICE [J].
BELHADJ, H ;
SIVIN, I ;
DIAZ, S ;
PAVEZ, M ;
TEJADA, AS ;
BRACHE, V ;
ALVAREZ, F ;
SHOUPE, D ;
BREAUX, H ;
MISHELL, DR ;
MCCARTHY, T ;
YO, V .
CONTRACEPTION, 1986, 34 (03) :261-267
[2]  
DIAZ S, 1980, CONTRACEPTION, V22, P259
[3]   LIFE-TABLE ANALYSIS OF IUDS - PROBLEMS AND RECOMMENDATIONS [J].
JAIN, AK ;
SIVIN, I .
STUDIES IN FAMILY PLANNING, 1977, 8 (02) :25-47
[4]   EFFECTIVE CONTRACEPTION WITH THE LEVONORGESTREL-RELEASING INTRAUTERINE-DEVICE - 12-MONTH REPORT OF A EUROPEAN MULTICENTER STUDY [J].
LUUKKAINEN, T ;
ALLONEN, H ;
HAUKKAMAA, M ;
HOLMA, P ;
PYORALA, T ;
TERHO, J ;
TOIVONEN, J ;
BATAR, I ;
LAMPE, L ;
ANDERSSON, K ;
ATTERFELDT, P ;
JOHANSSON, DB ;
NILSSON, S ;
NYGREN, KG ;
ODLIND, V ;
OLSSON, SE ;
RYBO, G ;
SIKSTROM, B ;
NIELSEN, NC ;
BUCH, A ;
OSLER, M ;
STEIER, A ;
ULSTEIN, M .
CONTRACEPTION, 1987, 36 (02) :169-179
[5]   5 YEARS EXPERIENCE OF INTRAUTERINE CONTRACEPTION WITH THE NOVA-T AND THE COPPER-T-200 [J].
LUUKKAINEN, T ;
ALLONEN, H ;
NIELSEN, NC ;
NYGREN, KG ;
PYORALA, T .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1983, 147 (08) :885-892
[6]  
NILSSON CG, 1981, LANCET, V1, P577
[7]  
NILSSON CG, 1983, FERTIL STERIL, V39, P187
[8]  
ROWE P, 1988, WHO79914 STUD
[9]  
ROWE PJ, 1987, CONTRACEPTION, V35, P363
[10]   MICRODOSE INTRAVAGINAL LEVONORGESTREL CONTRACEPTION - A MULTICENTER CLINICAL-TRIAL .1. CONTRACEPTIVE EFFICACY AND SIDE-EFFECTS [J].
ROWE, PJ .
CONTRACEPTION, 1990, 41 (02) :105-124