ONLINE DETERMINATION OF GLUCOSE-CONCENTRATION THROUGHOUT ANIMAL-CELL CULTURES BASED ON CHEMILUMINESCENT DETECTION OF HYDROGEN-PEROXIDE COUPLED WITH FLOW-INJECTION ANALYSIS

被引:28
作者
HUANG, YL
LI, SY
DREMEL, BAA
BILITEWSKI, U
SCHMID, RD
机构
[1] Department of Enzyme Technology, Gesellschaft für Biotechnologische Forschung GmbH, Braunschweig
关键词
FIA; CHEMILUMINESCENCE OF LUMINOL; ONLINE DETERMINATION; GLUCOSE; ANIMAL CELL CULTURE;
D O I
10.1016/0168-1656(91)90244-P
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
A flow-injection analysis (FIA) system for the on-line determination of glucose in animal cell cultures is described. The system is based on immobilized glucose oxidase (GOD). The hydrogen peroxide generated in the enzyme reaction is determined via a highly sensitive chemiluminescent reaction with luminol. Based on the measurement of the maximum emitted light intensity, the system was able to analyse hydrogen peroxide over the concentration range of 10(-7) to 10(-2) M. For glucose determination, the system has a linear range of 10(-5) to 5 x 10(-2) M glucose, with an r.s.d. of 3% at the 1 mM level (5 measurements). The influence of luminol and buffer concentrations, pH and temperature on the chemiluminescent reaction were investigated. The enzyme reactor used was stable for more than 4 weeks in continuous operation, and it was possible to analyse up to 20 samples per h. The system has been successfully applied to on-line monitoring of glucose concentration during an animal cell culture, designed for the production of human antithrombin III factor. Results obtained with the FIA system were compared with off-line results, obtained with a Yellow Springs Instrument Company Model 27 (YSI).
引用
收藏
页码:161 / 172
页数:12
相关论文
共 41 条
[1]   PEROXIDE OPTRODE BASED ON MICELLAR-MEDIATED CHEMI-LUMINESCENCE REACTION OF LUMINOL [J].
ABDELLATIF, MS ;
GUILBAULT, GG .
ANALYTICA CHIMICA ACTA, 1989, 221 (01) :11-17
[2]   CHEMILUMINESCENT ENZYME METHOD FOR GLUCOSE [J].
AUSES, JP ;
COOK, SL ;
MALOY, JT .
ANALYTICAL CHEMISTRY, 1975, 47 (02) :244-249
[3]   QUANTITATIVE-DETERMINATION OF BLOOD-GLUCOSE USING ENZYME INDUCED CHEMILUMINESCENCE OF LUMINOL [J].
BOSTICK, DT ;
HERCULES, DM .
ANALYTICAL CHEMISTRY, 1975, 47 (03) :447-452
[4]  
BRADLEY J, 1989, COMPUTER APPLICATIONS IN FERMENTATION TECHNOLOGY : MODELLING AND CONTROL OF BIOTECHNOLOGICAL PROCESSES, P47
[5]   A REVIEW OF REACTION DETECTION IN HPLC [J].
BRINKMAN, UAT .
CHROMATOGRAPHIA, 1987, 24 :190-200
[6]   SPLIT ZONE FLOW-INJECTION ANALYSIS - AN APPROACH TO AUTOMATED DILUTIONS [J].
CLARK, GD ;
RUZICKA, J ;
CHRISTIAN, GD .
ANALYTICAL CHEMISTRY, 1989, 61 (15) :1773-1778
[7]  
DAMEN CE, 1980, J ASSOC OFF ANA CHEM, V63, P476
[8]   QUINOPROTEIN GLUCOSE-DEHYDROGENASE AND ITS APPLICATION IN AN AMPEROMETRIC GLUCOSE SENSOR [J].
DCOSTA, EJ ;
HIGGINS, IJ ;
TURNER, APF .
BIOSENSORS, 1986, 2 (02) :71-87
[9]   CELLULAR AND ENVIRONMENTAL FACTORS AFFECTING SYNTHESIS AND EXCRETION OF METABOLITES [J].
DEMAIN, AL .
JOURNAL OF APPLIED CHEMISTRY AND BIOTECHNOLOGY, 1972, 22 (03) :345-&
[10]  
DUNN OJ, 1979, BASIC STATISTICS, P157