PRECISION AND ACCURACY OF A NONINVASIVE INERT-GAS WASHIN METHOD FOR DETERMINATION OF CARDIAC-OUTPUT IN MEN

被引:10
作者
NIELSEN, OW
HANSEN, S
GRONLUND, J
机构
[1] ODENSE UNIV,INST MED BIOL,DEPT PHYSIOL,DK-5230 ODENSE M,DENMARK
[2] INNOVISION AS,DK-5260 ODENSE S,DENMARK
关键词
INERT GAS REBREATHING; COMPUTER SIMULATION; ACETYLENE; NITROUS OXIDE; LUNG FUNCTION;
D O I
10.1152/jappl.1994.76.4.1560
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Stout et al. (J. Appl. Physiol. 38: 913-918, 1975) suggested an open-circuit multibreath (MB) inert gas method for determining pulmonary capillary blood flow (Qc) in anesthetized dogs receiving artificial ventilation. In the present work we investigated the accuracy and reproducibility of the MB method in nine healthy human subjects at spontaneous ventilation, and we compared the MB method with the inert gas rebreathing (RB) method. Qc was calculated at rest and during exercise at 50 or 100 W, and experimental errors were evaluated in computer simulations of a two-alveoli lung model. The calculated mean Qc values of the MB method were 5.56 +/- 1.23 (SD), 10.02 +/- 0.78, and 13.2 +/- 0.84 l/min, and the mean difference (MB Qc - RB Qc) was not significantly different (P > 0.05). The variation in Qc of the MB method was found to be significantly larger than that in Qc of the RB method (P < 0.01). Random measurement errors and uneven distribution of ventilation contributed to the experimental errors. We conclude that the MB method is inferior to the RB method but that the MB method may be useful under exercise conditions.
引用
收藏
页码:1560 / 1565
页数:6
相关论文
共 12 条
[1]  
ARMITAGE P, 1987, STATISTICAL METHODS
[2]  
BONDEPETERSEN F, 1980, AVIAT SPACE ENVIR MD, V51, P1214
[3]   DETERMINATION OF PULMONARY PARENCHYMAL TISSUE VOLUME AND PULMONARY CAPILLARY BLOOD FLOW IN MAN [J].
CANDER, L ;
FORSTER, RE .
JOURNAL OF APPLIED PHYSIOLOGY, 1959, 14 (04) :541-551
[4]   EFFECT OF THE REBREATHING PATTERN ON PULMONARY TISSUE VOLUME AND CAPILLARY BLOOD-FLOW [J].
KALLAY, MC ;
HYDE, RW ;
FAHEY, PJ ;
UTELL, MJ ;
PETERSON, BT ;
ORTIZ, CR .
JOURNAL OF APPLIED PHYSIOLOGY, 1985, 58 (06) :1881-1894
[5]   REPEATABILITY OF THE ACETYLENE REBREATHING METHOD IN MEASURING CARDIAC-OUTPUT - INFLUENCE OF ACETYLENE CONCENTRATION [J].
NIELSEN, OW ;
HANSEN, S ;
CHRISTENSEN, P ;
GRONLUND, J .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1990, 34 (05) :354-357
[6]   UNEVEN GAS MIXING DURING RE-BREATHING ASSESSED BY SIMULTANEOUSLY MEASURING DEAD SPACE [J].
PETRINI, MF ;
PETERSON, BT ;
HYDE, RW ;
LAM, V ;
UTELL, MJ ;
KALLAY, MC .
JOURNAL OF APPLIED PHYSIOLOGY, 1982, 53 (04) :930-939
[7]   LUNG-TISSUE VOLUME AND BLOOD-FLOW BY REBREATHING - THEORY [J].
PETRINI, MF ;
PETERSON, BT ;
HYDE, RW .
JOURNAL OF APPLIED PHYSIOLOGY, 1978, 44 (05) :795-802
[8]  
SACKNER MA, 1975, AM REV RESPIR DIS, V111, P157
[9]  
SAIDEL GM, 1981, B MATH BIOL, V43, P1
[10]   PULMONARY BLOOD-FLOW DETERMINED BY CONTINUOUS ANALYSIS OF PULMONARY N2O EXCHANGE [J].
STOUT, RL ;
WESSEL, HU ;
PAUL, MH .
JOURNAL OF APPLIED PHYSIOLOGY, 1975, 38 (05) :913-918