Copper nanoparticles-modified carbon paste transducer as a biosensor for determination of acetylcholine

被引:87
作者
Heli, H. [1 ]
Hajjizadeh, M. [2 ]
Jabbari, A. [2 ]
Moosavi-Movahedi, A. A. [1 ]
机构
[1] Univ Tehran, Inst Biochem & Biophys, Tehran, Iran
[2] KN Toosi Univ Technol, Dept Chem, Tehran, Iran
基金
美国国家科学基金会;
关键词
Copper; Nanoparticle; Acetylcholine; Nanobiosensor; Electrocatalysis; ELECTROCATALYTIC OXIDATION; COMPOSITE ELECTRODES; AMPEROMETRIC SENSOR; HYDROGEN-PEROXIDE; AMINO-ACIDS; OXIDE; ELECTROOXIDATION; PERFORMANCE; COMPLEX; CHOLINE;
D O I
10.1016/j.bios.2008.10.036
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The electrocatalytic oxidation of acetylcholine (Ach) on two different copper-based transducers, copper microparticles-modified carbon paste electrode (m-CPE) and copper nanoparticles-modified carbon paste electrode (n-CPE), was investigated. In the voltammograms recorded using m-CPE, a single anodic oxidation peak related to the oxidation of ACh was appeared which was related to the electrocatalytic oxidation of ACh via the electrogenerated Cu(III) species in an EC' mechanism. Using n-CPE, however, two overlapped anodic peaks appeared which were related to two fine tunable steps of oxidation. ACh oxidized on n-CPE with higher rates at low potentials with respect to m-CPE. The kinetic of the reaction was formulated and the charge-transfer resistance of the system was obtained both theoretically and experimentally. The catalytic rate constant, the transfer coefficient for the electrocatalytic oxidation and the diffusion coefficients for ACh were reported using chronoamperometry, pseudo-steady-state polarization measurement and electrochemical impedance spectroscopy. Sensitive and time-saving sensing procedures in both batch and flow systems were developed for the analysis of ACh, and the corresponding analytical parameters were reported. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:2328 / 2333
页数:6
相关论文
共 39 条
[1]  
[Anonymous], 1994, STAT ANAL CHEM
[2]  
Bard A. J., 2001, ELECTROCHEMICAL METH
[3]   APPLICATION OF PROBE BEAM DEFLECTION TO STUDY THE ELECTROOXIDATION OF COPPER IN ALKALINE MEDIA [J].
BRISARD, GM ;
RUDNICKI, JD ;
MCLARNON, F ;
CAIRNS, EJ .
ELECTROCHIMICA ACTA, 1995, 40 (07) :859-865
[4]   Copper dispersed into polyaniline films as an amperometric sensor in alkaline solutions of amino acids and polyhydric compounds [J].
Casella, IG ;
Cataldi, TRI ;
Guerrieri, A ;
Desimoni, E .
ANALYTICA CHIMICA ACTA, 1996, 335 (03) :217-225
[5]  
DAVIES P, 1976, LANCET, V2, P1403
[6]  
Davis K. L., 1979, BRAIN ACETYLCHOLINE
[7]  
Fleischmann M., 1972, JCHEMSOC PERKIN, VII, P1396, DOI DOI 10.1039/P29720001396
[8]   AN ENZYME-REACTOR FOR ELECTROCHEMICAL MONITORING OF CHOLINE AND ACETYLCHOLINE - APPLICATIONS IN HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY, BRAIN-TISSUE, MICRODIALYSIS AND CEREBROSPINAL-FLUID [J].
FLENTGE, F ;
VENEMA, K ;
KOCH, T ;
KORF, J .
ANALYTICAL BIOCHEMISTRY, 1992, 204 (02) :305-310
[9]   Catalysis of dioxygen reduction to hydrogen peroxide at the surface of carbon paste electrodes modified by 1,4-naphthoquinone and some of its derivatives [J].
Golabi, SM ;
Raoof, JB .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1996, 416 (1-2) :75-82
[10]   Electrocatalytic oxidation and determination of deferasirox and deferiprone on a nickel oxyhydroxide-modified electrode [J].
Hajjizadeh, M. ;
Jabbari, A. ;
Heli, H. ;
Moosavi-Movahedi, A. A. ;
Shafiee, A. ;
Karimian, K. .
ANALYTICAL BIOCHEMISTRY, 2008, 373 (02) :337-348