EVALUATION OF PH FIELD-EFFECT TRANSISTOR MEASUREMENT SIGNALS BY NEURAL NETWORKS

被引:23
作者
HITZMANN, B
KULLICK, T
机构
[1] Institut für Technische Chemie, Universität Hannover, 30167 Hannover
关键词
BIOSENSORS; ENZYME FIELD EFFECT TRANSISTORS; FLOW INJECTION; NEURAL NETWORKS; EVALUATION METHODS;
D O I
10.1016/0003-2670(94)80307-2
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A method is described which allows to evaluate analyte concentrations from flow-injection analysis signals of a pH field effect transistor (pH-FET) detector independently of the buffer capacity of the probe. The enzyme penicillin-G amidase was employed as the biocompound to monitor penicillin concentrations. Measurements have been carried out by using samples with various penicillin concentrations (penicillin-G: 1.5, 2.5, 5.0, 7.5 and 10.0 g/l) as well as various buffer ion concentrations (phosphate: 5, 15, 20, 25, 35, 45 and 50 mM). Depending on the penicillin concentration as well as the buffer ion concentration the peak shaped measurement signals did not only change their height but also their contour. Using the standard evaluation methods (peak height, integral or width) no unambiguous relation to the considered concentration could be found. In contrast to this, neural networks have been found to be able to evaluate the different contours. The relative errors were 4.7% for the determination of the penicillin concentration and 4.9% for the buffer ion concentration. The possibility of broadening the scope of this method to other pH-FET systems is discussed.
引用
收藏
页码:243 / 249
页数:7
相关论文
共 9 条
[1]  
CAMPMAJO C, 1992, ANALUSIS, V20, P127
[2]   RESPONSE OF AN ENZYME-MODIFIED PH-SENSITIVE ION-SELECTIVE DEVICE - CONSIDERATION OF THE INFLUENCE OF THE BUFFERING CAPACITY OF THE ANALYTE SOLUTION [J].
EDDOWES, MJ .
SENSORS AND ACTUATORS, 1985, 7 (02) :97-115
[3]   NEURAL NETWORK BASED RECOGNITION OF FLOW-INJECTION PATTERNS [J].
HARTNETT, M ;
DIAMOND, D ;
BARKER, PG .
ANALYST, 1993, 118 (04) :347-354
[4]  
HITZMANN B, 1993, BIOFORUM, V16, P450
[5]  
KRUSE H, 1991, PROGRAMMIERUNG NEURO
[6]   REMOVING THE INFLUENCE OF BUFFER CONCENTRATION ON THE RESPONSE OF ENZYME FIELD-EFFECT TRANSISTORS BY USING ADDITIONAL MEMBRANES [J].
SHULGA, AA ;
STRIKHA, VI ;
SOLDATKIN, AP ;
ELSKAYA, AV ;
MAUPAS, H ;
MARTELET, C ;
CLECHET, P .
ANALYTICA CHIMICA ACTA, 1993, 278 (02) :233-236
[7]   GLUCOSE-SENSITIVE FIELD-EFFECT TRANSISTOR WITH ADDITIONAL NAFION MEMBRANE - REDUCTION OF INFLUENCE OF BUFFER CAPACITY ON THE SENSOR RESPONSE AND EXTENSION OF ITS DYNAMIC-RANGE [J].
SOLDATKIN, AP ;
ELSKAYA, AV ;
SHULGA, AA ;
NETCHIPOROUK, LI ;
HENDJI, AMN ;
JAFFREZICRENAULT, N ;
MARTELET, C .
ANALYTICA CHIMICA ACTA, 1993, 283 (02) :695-701
[8]   NEURONAL NETWORKS FOR EVALUATION OF MEASURING SIGNALS FROM FLOW-INJECTION ANALYSIS [J].
WASSMANN, A ;
HITZMANN, B .
CHEMIE INGENIEUR TECHNIK, 1993, 65 (08) :947-949
[9]   NEURAL NETWORKS - A NEW METHOD FOR SOLVING CHEMICAL PROBLEMS OR JUST A PASSING PHASE [J].
ZUPAN, J ;
GASTEIGER, J .
ANALYTICA CHIMICA ACTA, 1991, 248 (01) :1-30