DUAL ENERGY X-RAY ABSORPTIOMETRY - THE EFFECTS OF BEAM HARDENING ON BONE-DENSITY MEASUREMENTS

被引:60
作者
BLAKE, GM
MCKEENEY, DB
CHHAYA, SC
RYAN, PJ
FOGELMAN, I
机构
[1] Department of Nuclear Medicine, Guy's Hospital, London, SE1 9RT, St. Thomas Street
关键词
DUAL ENERGY X-RAY ABSORPTIOMETRY; BONE DENSITY; BODY THICKNESS; BEAM HARDENING;
D O I
10.1118/1.596834
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
X-ray tubes have superseded radionuclide sources for dual photon absorptiometry of the spine and hip. However, the use of a polyenergetic spectrum is a potential source of error for x-ray absorptiometers since beam hardening may result in a nonlinear measurement scale for bone mineral density (BMD). A quantitative study of the effects of beam hardening on measurements made with a commercial dual energy x-ray scanner has been performed. Bone was represented by layers of aluminum of linearly increasing thickness which were scanned under water thicknesses ranging from 0 to 25 cm to represent different body thicknesses of soft tissue. Beam hardening had two effects on measured BMD: (i) at a constant true BMD, measured BMD varied with water thickness; (ii) at a constant water thickness, the BMD scale was not precisely linear. For conditions appropriate to spine and hip studies (BMD values in the range 0.7 to 1.4 g/cm2 and body thickness between 15 and 25 cm) the maximum deviation of measured BMD from a linear scale was 0.023 g/cm2, while the root-mean-square deviation (0.01 g/cm2) was comparable to the measurement precision for a spine or femoral neck scan (about 1%). The largest departures from linearity were found to occur at the thinnest water thicknesses for BMD values in the range 0.2 to 0.6 g/cm2. The effect of scale nonlinearity on the results of longitudinal studies was examined: for a spine scan at 20-cm body thickness, measured changes in BMD slightly overestimated the true change and implied an error of 0.15%/year for a measurement of a true rate of loss of 3%/year in a postmenopausal woman.
引用
收藏
页码:459 / 465
页数:7
相关论文
共 25 条
  • [1] X-RAY DUAL-PHOTON ABSORPTIOMETRY - A NEW METHOD FOR THE MEASUREMENT OF BONE-DENSITY
    CULLUM, ID
    ELL, PJ
    RYDER, JP
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1989, 62 (739) : 587 - 592
  • [2] DAVIE MWJ, 1990, CURRENT RES OSTEOPOR, P33
  • [3] DUNN WL, 1987, J NUCL MED, V28, P1751
  • [4] MEASUREMENT OF BONE-MINERAL CONTENT IN HUMAN VERTEBRAE AND HIP BY DUAL PHOTON-ABSORPTIOMETRY
    DUNN, WL
    WAHNER, HW
    RIGGS, BL
    [J]. RADIOLOGY, 1980, 136 (02) : 485 - 487
  • [5] THE ERROR DUE TO FAT INHOMOGENEITY IN LUMBAR SPINE BONE-MINERAL MEASUREMENTS
    FARRELL, TJ
    WEBBER, CE
    [J]. CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1989, 10 (01): : 57 - 64
  • [6] HANSEN MA, 1990, J NUCL MED, V31, P1156
  • [7] TISSUE-ANALYSIS BY DUAL-ENERGY COMPUTED-TOMOGRAPHY
    HAWKES, DJ
    JACKSON, DF
    PARKER, RP
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1986, 59 (702) : 537 - 542
  • [8] PHOTON MASS ATTENUATION AND ENERGY-ABSORPTION COEFFICIENTS FROM 1 KEV TO 20 MEV
    HUBBELL, JH
    [J]. INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1982, 33 (11): : 1269 - 1290
  • [9] QUANTITATIVE DIGITAL RADIOGRAPHY VERSUS DUAL PHOTON-ABSORPTIOMETRY OF THE LUMBAR SPINE
    KELLY, TL
    SLOVIK, DM
    SCHOENFELD, DA
    NEER, RM
    [J]. JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 1988, 67 (04) : 839 - 844
  • [10] KOTZI PO, 1990, CURRENT RES OSTEOPOR, P34