ASSESSMENT OF DUST AND ENDOTOXIN LEVELS IN THE WORKING ENVIRONMENT OF DUTCH PIG FARMERS - A PRELIMINARY-STUDY

被引:33
作者
ATTWOOD, P
VERSLOOT, P
HEEDERIK, D
DEWIT, R
BOLEIJ, JSM
机构
[1] AGR UNIV WAGENINGEN, DEPT ENVIRONM & TROP HLTH, GEN FOULKESWEG 43, 6703 BM WAGENINGEN, NETHERLANDS
[2] AGR UNIV WAGENINGEN, DEPT AIR POLLUT, 6703 BM WAGENINGEN, NETHERLANDS
关键词
D O I
10.1093/annhyg/30.2.201
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
This preliminary study quantified the levels of airborne dust and endotoxins present in pig confinement buidings. The dust was separated into three size fractions, <EQ 3.5, .ltoreq. 8.5 and < 51.2 .mu.m, using cyclone pre-separators and a modified cassette holder for total dust. The results indicate that there is a large day-to-day variation in total dust determined in a single confinement building and that the smallest fraction .ltoreq. 3.5 .mu.m varies from building to building but not in a single building. The levels of endotoxin determined in this study were similar to those found in other studies but indicated that there is a significant enrichment of endotoxin in the size fraction 3.5-8.5 .mu.m. The implications from this are that the assessment of the potential health risk to the farmer from endotoxin present in the airborne dust must be assessed using a biologically relevant cirterion based on particle penetration into the thoracic region of the exposed farmer''s lung. The current methods of looking at endotoxin levels in respirable and total dust give little information in regard to the potential health risk.
引用
收藏
页码:201 / 208
页数:8
相关论文
共 21 条