COLOR DOPPLER DIAGNOSIS OF MECHANICAL PROSTHETIC MITRAL REGURGITATION - USEFULNESS OF THE FLOW CONVERGENCE REGION PROXIMAL TO THE REGURGITANT ORIFICE

被引:29
作者
BARGIGGIA, GS
TRONCONI, L
RAISARO, A
RECUSANI, F
RAGNI, T
VALDESCRUZ, LM
SAHN, DJ
MONTEMARTINI, C
机构
[1] POLICLIN SAN MATTEO,IST RIC & CURA CARETTERE SC,DIV CARDIAC SURG,PAVIA,ITALY
[2] UNIV CALIF SAN DIEGO,DIV PEDIAT CARDIOL,LA JOLLA,CA 92093
关键词
D O I
10.1016/0002-8703(90)90127-J
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
In prosthetic or paravalvular prosthetic mitral regurgitation, transthoracic color Doppler flow mapping can sometimes fail to detect the regurgitant jet within the left atrium because of the shadowing by the prosthetic valve. To overcome this limitation, we assessed the utility of color Doppler visualization of the flow convergence region (FCR) proximal to the regurgitant orifice in 20 consecutive patients with mechanical prosthetic mitral regurgitation documented by surgery and cardiac catheterization (13 of 20 patients). In addition, we studied 33 patients with normally functioning mitral prostheses. Doppler studies were performed in the apical, subcostal, and parasternal long-axis views. An FCR was detected in 95% (19 of 20) of patients with prosthetic mitral regurgitation. A jet area in the left atrium was detected in 60% (12 of 20) of patients. In 18 of 19 patients with Doppler-detected FCR, the site of the leak was correctly identified by observing the location of the FCR. A trivial jet area was detected in eight patients with a normally functioning mitral prosthesis; in none was an FCR identified. Thus color Doppler visualization of the FCR proximal to the regurgitant orifice is superior to the jet area in the diagnosis of mechanical prosthetic mitral regurgitation. Moreover, FCR permits localization of the site of the leak with good accuracy. © 1990.
引用
收藏
页码:1137 / 1142
页数:6
相关论文
共 31 条
[1]   DOPPLER AND ECHOCARDIOGRAPHIC FEATURES OF NORMAL AND DYSFUNCTIONING BIOPROSTHETIC VALVES [J].
ALAM, M ;
ROSMAN, HS ;
LAKIER, JB ;
KEMP, S ;
KHAJA, F ;
HAUTAMAKI, K ;
MAGILLIGAN, DJ ;
STEIN, PD .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1987, 10 (04) :851-858
[2]  
AZUMA SS, 1985, J AM COLL CARDIOL, V5, P527
[3]  
BARGIGGIA G, 1988, CIRCULATION S2, V78, P609
[4]  
BARGIGGIA GS, 1989, EUR HEART J, P405
[5]  
CAPE EG, 1989, ECHOCARDIOGR-J CARD, V6, P371
[6]   PITFALLS IN THE DIAGNOSIS OF PERIPROSTHETIC VALVULAR REGURGITATION BY PULSED DOPPLER ECHOCARDIOGRAPHY [J].
COME, PC .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1987, 9 (05) :1176-1179
[7]  
CURRIE P J, 1989, Journal of the American College of Cardiology, V13, p69A
[8]  
DANIEL WG, 1988, CIRCULATION S2, V78, P607
[9]   EVALUATION OF BJORK-SHILEY PROSTHETIC VALVES BY REAL-TIME TWO-DIMENSIONAL DOPPLER ECHOCARDIOGRAPHIC FLOW MAPPING [J].
DITTRICH, H ;
NICOD, P ;
HOIT, B ;
DALTON, N ;
SAHN, D .
AMERICAN HEART JOURNAL, 1988, 115 (01) :133-138
[10]  
FAN PH, 1987, CIRCULATION, V76, P448