EXPONENTIAL FITTING OF PRESSURE-VOLUME CURVES - CONFIDENCE-LIMITS AND SENSITIVITY TO NOISE

被引:8
作者
EIDELMAN, DH [1 ]
GHEZZO, H [1 ]
BATES, JHT [1 ]
机构
[1] MCGILL UNIV,ROYAL VICTORIA HOSP,MONTREAL H3A 1A1,QUEBEC,CANADA
关键词
curve fitting; exponential analysis;
D O I
10.1152/jappl.1990.69.4.1538
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
It has recently become common to model the static pressure-volume curve of the lung as a monoexponential function of the form V = A - Be(-KP), where V is volume and P is transpulmonary pressure. The parameters A, B, and particularly K have been employed as descriptors of the intrinsic mechanical properties of the lung. The purpose of the present study was to investigate the sensitivities of A, B, and K to noise in measurements of P and V and to incompleteness of data. Using Monte-Carlo simulation, we found that the presence of typical levels of noise in P led to biased estimates of K and that the 95% confidence intervals about A and K were large compared with the parameter values themselves. These effects were increased as points were systematically removed from either end of the data set. These findings show that values of K estimated from PV data are difficult to interpret without accompanying confidence intervals.
引用
收藏
页码:1538 / 1541
页数:4
相关论文
共 20 条
[1]   PHYSICAL PROPERTIES OF THE LUNG IN CHRONIC OBSTRUCTIVE PULMONARY EMPHYSEMA [J].
CHERNIACK, RM .
JOURNAL OF CLINICAL INVESTIGATION, 1956, 35 (04) :394-404
[3]   EXPONENTIAL ANALYSIS OF ELASTIC RECOIL AND AGING IN HEALTHY-MALES AND FEMALES [J].
COLEBATCH, HJH ;
GREAVES, IA ;
NG, CKY .
JOURNAL OF APPLIED PHYSIOLOGY, 1979, 47 (04) :683-691
[4]   USE OF AN EXPONENTIAL FUNCTION FOR ELASTIC RECOIL [J].
COLEBATCH, HJH ;
NG, CKY ;
NIKOV, N .
JOURNAL OF APPLIED PHYSIOLOGY, 1979, 46 (02) :387-393
[5]  
COLEBATCH HJH, 1985, B EUR PHYSIOPATH RES, V21, P439
[6]   ELASTIC BEHAVIOR OF LUNG IN PATIENTS WITH AIRWAY OBSTRUCTION [J].
FINUCANE, KE ;
COLEBATCH, HJ .
JOURNAL OF APPLIED PHYSIOLOGY, 1969, 26 (03) :330-+
[7]  
GIBSON GJ, 1979, AM REV RESPIR DIS, V129, P799
[8]   ALVEOLAR SIZE AS A DETERMINANT OF PULMONARY DISTENSIBILITY IN MAMMALIAN LUNGS [J].
HABER, PS ;
COLEBATCH, HJH ;
NG, CKY ;
GREAVES, IA .
JOURNAL OF APPLIED PHYSIOLOGY, 1983, 54 (03) :837-845
[9]  
MACKLEM PT, 1963, AM REV RESPIR DIS, P47
[10]   VARIABILITY IN MEASUREMENTS OF PRESSURE-VOLUME CURVES IN NORMAL SUBJECTS [J].
MCCUAIG, KE ;
VESSAL, S ;
COPPIN, K ;
WIGGS, BJR ;
DAHLBY, R ;
PARE, PD .
AMERICAN REVIEW OF RESPIRATORY DISEASE, 1985, 131 (04) :656-658