DIAGNOSIS OF ABDOMINAL VENOUS THROMBOSIS BY MEANS OF SPIN-ECHO AND GRADIENT-ECHO MR IMAGING - ANALYSIS WITH RECEIVER OPERATING CHARACTERISTIC CURVES

被引:24
作者
ARRIVE, L [1 ]
MENU, Y [1 ]
DESSARTS, I [1 ]
DUBRAY, B [1 ]
VULLIERME, MP [1 ]
VILGRAIN, V [1 ]
NAJMARK, D [1 ]
NAHUM, H [1 ]
机构
[1] HOP ST LOUIS,DEPT BIOSTAT,F-75010 PARIS,FRANCE
关键词
ABDOMEN; MR STUDIES; BLOOD; FLOW DYNAMICS; BLOOD VESSELS; MAGNETIC RESONANCE (MR); PULSE SEQUENCES; THROMBOSIS; VENOUS; VEINS;
D O I
10.1148/radiology.181.3.1947078
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The authors compared the accuracy of spin-echo (SE) and gradient-echo (GRE) magnetic resonance images in diagnosis of abdominal venous thrombosis. Images of 292 abdominal veins in 72 patients were reviewed in a blinded manner by three radiologists, with seven levels of confidence for diagnosis. Corroborative studies proved thrombosis (n = 95) and vessel patency (n = 197). Receiver operating characteristic (ROC) curves were constructed for SE images alone, GRE images alone, and SE and GRE images combined. At specificities of 90% and 95%, thrombi were identified with sensitivities, respectively, of 76% and 63% with SE images, 74% and 58% with GRE images, and 88% and 82% with combined SE and GRE images. The area under the ROC curve for SE and GRE images combined (0.958 +/- 0.011 [standard deviation]) was significantly larger (P < .001) than that for SE images alone (0.913 +/- 0.018) and GRE images alone (0.921 +/- 0.016). It is concluded that combination of SE and GRE images significantly increases the accuracy of diagnosis of abdominal venous thrombosis.
引用
收藏
页码:661 / 668
页数:8
相关论文
共 27 条
  • [1] MR APPEARANCE OF THE LIVER AFTER PARTIAL-HEPATECTOMY
    ARRIVE, L
    HRICAK, H
    GOLDBERG, HI
    THOENI, RF
    MARGULIS, AR
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1989, 152 (06) : 1215 - 1220
  • [2] AQUEDUCTAL STENOSIS - EVALUATION WITH GRADIENT-ECHO RAPID MR IMAGING
    ATLAS, SW
    MARK, AS
    FRAM, EK
    [J]. RADIOLOGY, 1988, 169 (02) : 449 - 453
  • [3] VASCULAR INTRACRANIAL LESIONS - APPLICATIONS OF GRADIENT-ECHO MR IMAGING
    ATLAS, SW
    MARK, AS
    FRAM, EK
    GROSSMAN, RI
    [J]. RADIOLOGY, 1988, 169 (02) : 455 - 461
  • [4] BLOOD-FLOW EFFECTS IN MAGNETIC-RESONANCE IMAGING
    AXEL, L
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1984, 143 (06) : 1157 - 1166
  • [5] FLOW PHENOMENA IN MR IMAGING
    BRADLEY, WG
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1988, 150 (05) : 983 - 994
  • [6] MAXIMUM-LIKELIHOOD ESTIMATION OF PARAMETERS OF SIGNAL-DETECTION THEORY AND DETERMINATION OF CONFIDENCE INTERVALS - RATING-METHOD DATA
    DORFMAN, DD
    ALF, E
    [J]. JOURNAL OF MATHEMATICAL PSYCHOLOGY, 1969, 6 (03) : 487 - &
  • [7] MAGNETIC-RESONANCE ANGIOGRAPHY
    DUMOULIN, CL
    HART, HR
    [J]. RADIOLOGY, 1986, 161 (03) : 717 - 720
  • [8] QUANTIFICATION OF BLOOD-FLOW WITH DYNAMIC MR IMAGING AND PRESATURATION BOLUS TRACKING
    EDELMAN, RR
    MATTLE, HP
    KLEEFIELD, J
    SILVER, MS
    [J]. RADIOLOGY, 1989, 171 (02) : 551 - 556
  • [9] MR ANGIOGRAPHY AND DYNAMIC FLOW EVALUATION OF THE PORTAL VENOUS SYSTEM
    EDELMAN, RR
    ZHAO, B
    LIU, C
    WENTZ, KU
    MATTLE, HP
    FINN, JP
    MCARDLE, C
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1989, 153 (04) : 755 - 760
  • [10] NMR RELAXATION-TIMES OF BLOOD - DEPENDENCE ON FIELD-STRENGTH, OXIDATION-STATE, AND CELL INTEGRITY
    GOMORI, JM
    GROSSMAN, RI
    YUIP, C
    ASAKURA, T
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1987, 11 (04) : 684 - 690