OVERALL AND ZONAL ENERGY END-USE IN AN ENERGY CONSCIOUS OFFICE BUILDING

被引:3
作者
ASHLEY, R
REYNOLDS, JS
机构
[1] Department of Architecture, University of Oregon, Eugene
关键词
D O I
10.1016/0038-092X(94)90083-E
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 [动力工程及工程热物理]; 0820 [石油与天然气工程];
摘要
An office building of unusual design has been monitored for more than three years. Numerous submeters allow tracking of energy end use. The building was designed to make significant use of daylighting, with some passive solar heating, and an emphasis on night ventilation cooling of thermal mass. The overall building end usages are compared to those of three zones of varying orientation, spatial character, size, and population. Insights about daylight-sensing controls of indirect electric lighting, ''task heating,'' and night ventilation of mass and air quality are presented.
引用
收藏
页码:75 / 83
页数:9
相关论文
共 6 条
[1]
BAKER MS, 1991, P AM SOLAR ENERGY SO
[2]
CARTWRIGHT V, 1991, 1991 P WORLD C INT S
[3]
HEERWAGEN J, 1990, EMERALD PUD BUILDING
[4]
REYNOLDS JS, 1988, HLTH BUILDINGS 88, V2
[5]
REYNOLDS JS, 1987, 12TH P NAT PASS SOL
[6]
STEIN B, 1992, MECHANICAL ELECTRICA