AN INTERNATIONAL INTERCOMPARISON OF MARINE ATMOSPHERIC RADON-222 MEASUREMENTS IN BERMUDA

被引:9
作者
COLLE, R
UNTERWEGER, MP
HODGE, PA
HUTCHINSON, JMR
WHITTLESTONE, S
POLIAN, G
ARDOUIN, B
KAY, JG
FRIEND, JP
BLOMQUIST, BW
NADLER, W
DANG, TT
LARSEN, RJ
HUTTER, AR
机构
[1] AUSTRALIAN NUCL SCI & TECHNOL ORG, MENAI, NSW 2234, AUSTRALIA
[2] CEA, CTR FAIBLES RADIOACTIV, MIXTE LAB, CNRS, GIF SUR YVETTE, FRANCE
[3] DREXEL UNIV, DEPT CHEM, ATMOSPHER CHEM LABS, PHILADELPHIA, PA 19104 USA
[4] US DOE, ENVIRONM MEASUREMENTS LAB, NEW YORK, NY 10014 USA
关键词
D O I
10.1029/95JD01535
中图分类号
P4 [大气科学(气象学)];
学科分类号
0706 ; 070601 ;
摘要
As part of an international measurement intercomparison of instruments used to measure atmospheric Rn-222, four participating laboratories made nearly simultaneous measurements of Rn-222 activity concentration in commonly sampled, ambient air over approximately a 2-week period, and three of these four laboratories participated in the measurement comparison of 14 introduced samples with known, but undisclosed (''blind'') Rn-222 activity concentrations that could be related to U.S, national standards. The standardized sample additions were obtained with a calibrated Ra-226 source and a specially designed manifold used to obtain well-known dilution factors from simultaneous flow rate measurements. The exercise was conducted in Bermuda in October 1991. The Rn-222 activity concentrations in ambient Bermudian air over the course of the intercomparison ranged from a few hundredths to about 2 Bq m(-3), while the standardized sample additions covered a range from approximately 2.5 to 35 Bq m(-3). The overall uncertainty in the latter concentrations was in the general range of 10% at a 3 standard deviation uncertainty interval. The results of the intercomparison indicated that two of the laboratories were within very good agreement with the standard additions and almost within expected statistical variations. These same two laboratories, however, at lower ambient concentrations, exhibited a systematic difference with an averaged offset of roughly 0.3 Bq m(-3). The third laboratory participating in the measurement of standardized sample additions was systematically low by about 65-70%, which was also confirmed in their ambient air concentration measurements. The fourth laboratory, participating in only the ambient measurement part of the intercomparison, was also systematically low by at least 40% with respect to the first two aforementioned laboratories.
引用
收藏
页码:16617 / 16638
页数:22
相关论文
共 11 条