BIOELECTROCHEMICAL DETERMINATION OF LACTIC AND MALIC-ACIDS IN WINE

被引:45
作者
PALLESCHI, G [1 ]
VOLPE, G [1 ]
COMPAGNONE, D [1 ]
LANOTTE, E [1 ]
ESTI, M [1 ]
机构
[1] UNIV MOLISE,DISTAAM,I-86100 CAMPOBASSO,ITALY
关键词
D O I
10.1016/0039-9140(94)E0044-R
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Electroanalytical methods based on biosensor technology and differential PH measurement for the determination Pf L-lactic and L-malic acids in wine were developed. Lactic acid was determined according to two procedures consisting of the use of two lactate electrochemical biosensors, one based on a Clark 02 probe and the other based on the H2O2 probe. The two probes were assembled employing a polymeric membrane where the enzyme lactate oxidase was previously immobilized. Both sensors exhibited high storage and operational stabilities, and good reproducibility when used in wine matrix. Measurement of lactate was carried out using two different flow-through cells assembled with the lactate probes. The low detection limit of these probes and the relatively high concentration of lactate in wine samples required a serial dilution in the range 1:100 to 1:200, thus eliminating all potential electrochemical or enzyme interferences present in the sample. Malic acid was determined using a differential commercially available pH-meter and an enzymatic procedure. For this analysis, we employed the malic enzyme (EC 1.1.1.40) and the NADP+ cofactor. The pH variation due to the action of this enzyme on malic acid was found to be proportional to the malic acid present in the sample. Experimental parameters such as pH, temperature, and co-factor concentration were optimized, resulting in malate determination in less than 1 min with good reproducibility. Various samples of wine and wine musts were assayed for lactate with the two biosensor procedures, and for malate with differential pH-metry. The results when compared with those obtained with the commonly used spectrophotometric procedure correlated well.
引用
收藏
页码:917 / 923
页数:7
相关论文
共 12 条
[1]   FLOW-INJECTION DETERMINATION OF MALATE WITH IMMOBILIZED MALATE-DEHYDROGENASE [J].
ALMUIABED, AM ;
TOWNSHEND, A .
ANALYTICA CHIMICA ACTA, 1989, 221 (02) :337-340
[2]  
CHEMNITIUS GC, 1989, ANAL LETT, V22, P2987
[3]  
LAFONLAFOURCADE S, 1975, FACTORS MALOLACTIC F
[4]   ELECTROMETRIC METHOD FOR MEASUREMET OF SMALL PH CHANGES IN BIOLOGICAL SYSTEMS [J].
LUZZANA, M ;
PERRELLA, M ;
ROSSIBER.L .
ANALYTICAL BIOCHEMISTRY, 1971, 43 (02) :556-&
[5]  
LUZZANA M, 1983, CLIN CHEM, V29, P80
[6]   A LACTATE ELECTRODE WITH LACTATE OXIDASE IMMOBILIZED ON NYLON NET FOR BLOOD-SERUM SAMPLES IN FLOW SYSTEMS [J].
MASCINI, M ;
MOSCONE, D ;
PALLESCHI, G .
ANALYTICA CHIMICA ACTA, 1984, 157 (01) :45-51
[7]  
MASCINI M, 1987, CLIN CHEM, V33, P591
[8]   L-MALATE-SENSING ELECTRODE BASED ON MALATE-DEHYDROGENASE AND NADH OXIDASE [J].
MIZUTANI, F ;
YABUKI, S ;
ASAI, M .
ANALYTICA CHIMICA ACTA, 1991, 245 (02) :145-150
[9]  
MOLLERING H, 1985, METHOD ENZYMAT AN, V20, P39
[10]  
NOLL F, 1984, METHOD ENZYMAT AN, V6, P582