INTEGRATED PYROELECTRIC DETECTOR ARRAYS WITH THE SENSOR MATERIAL PVDF

被引:20
作者
PLOSS, B [1 ]
LEHMANN, P [1 ]
SCHOPF, H [1 ]
LESSLE, T [1 ]
BAUER, S [1 ]
THIEMANN, U [1 ]
机构
[1] UNIV STUTTGART,INST HALBLEITERTECH,W-7000 STUTTGART 80,GERMANY
关键词
D O I
10.1080/00150199008211417
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Integrated PVDF pyroelectric radiation detectors have been made, using a simple technique to interface the pyroelectric material with the silicon substrate. The silicon substrates incorporate the electronics for a 8x1 array and a 2x2 array. The relevant sensor parameters voltage responsivity, detectivity and the thermal crosstalk are measured within a frequency range from 0.01 Hz to 5000 Hz. With the 400 pm thick silicon substrate the voltage respgnsivity is typically 100 V/W, the maximum detectivity is 7x10 [formula ommited] at a frequency of 30 Hz. An improvement of both voltage responsivity and detectivity is possible by reducing the heat loss to the silicon substrate. This can be realized by a reduction of the substrate thickness, at least underneath the detector area. A further improvement is possible by a reduction of the capacity of the electronic circuit on the silicon chip and by the use of ferroelectric materials with higher pyroelectric coefficients, for example TGS. © 1990, Taylor & Francis Group, LLC. All rights reserved.
引用
收藏
页码:223 / 228
页数:6
相关论文