ELECTROCHEMICAL ENZYME-IMMUNOASSAY FOR DETECTION OF TOXIC-SUBSTANCES

被引:15
作者
ODALY, JP
ZHAO, JG
BROWN, PA
HENKENS, RW
机构
[1] Enzyme Technology Research Group, Inc., Durham, NC
关键词
ELECTROCHEMICAL ENZYME-LINKED IMMUNOASSAY; IMMUNOSENSORS; TOXIC SUBSTANCES; COLLOIDAL GOLD;
D O I
10.1016/0141-0229(92)90155-H
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Sensors that provide reliable, rapid measurement of toxic substances are needed to solve significant human health and safety problems. We developed a new biosensor design that combines the advantages of immunoassay with electrochemical response. We established that this enzyme-linked immunosensor measures toxic substances in biological samples. The biosensor consists of two major elements: (1) an electrical conducting layer having immobilized enzyme, polyclonal or monoclonal antibodies, and other necessary reagents, and (2) the electronic components used in the signal readout. The result is an amperometric immunoassay based on coupling the immunochemical reaction to the enzyme electrode response by using a soluble, electrochemically active mediator. The specific question addressed was: Does the system's immunochemical detection reliably respond at sufficiently low analyte concentrations? We present our results in these areas: (1) enzyme immobilization on colloidal gold; (2) colloidal gold-enzyme deposition on the electrode surface; (3) mediator-antigen conjugate synthesis; (4) antibody incorporation at the electrode surface; (5) bioelectrode characterization and optimization; and (6) immunosensor demonstration to detect antigen. Sensors that employ immunochemical detection will have broad applicability to detect/diagnose toxic substances in biological samples such as blood and urine and in environmental samples such as wastewater and drinking water.
引用
收藏
页码:299 / 302
页数:4
相关论文
共 15 条
  • [1] CRUMBLISS AL, 1990, BIOSENSOR TECHNOLOGY, pCH13
  • [2] EGGERS HM, 1982, CLIN CHEM, V28, P1848
  • [3] VARIATION IN AFFINITIES OF ANTIBODIES DURING IMMUNE RESPONSE
    EISEN, HN
    SISKIND, GW
    [J]. BIOCHEMISTRY, 1964, 3 (07) : 996 - &
  • [4] GALLATI H, 1979, J CLIN CHEM CLIN BIO, V17, P1
  • [5] ELECTROCHEMICAL ENZYME-IMMUNOASSAY
    HALSALL, HB
    HEINEMAN, WR
    JENKINS, SH
    WEHMEYER, KR
    DOYLE, MJ
    WRIGHT, DS
    [J]. JOURNAL OF RESEARCH OF THE NATIONAL BUREAU OF STANDARDS, 1988, 93 (03): : 491 - 493
  • [6] HARSHAM S, 1988, METHODS ENZYMOLOGY, V165
  • [7] Henkens R. W., 1991, J INORG BIOCHEM, V43, P120
  • [8] HENKENS RW, 1987, RECL TRAV CHIM PAY B, V106, P298
  • [9] HENKENS RW, 1990, 5TH P INT BIOT C COP
  • [10] REDUCTION OF CHLORINE ON CARBON IN ALCL3-KCL-NACL MELTS
    HOLLECK, GL
    [J]. JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1972, 119 (09) : 1158 - &