CHARACTERIZATION OF SAMPLING SCHEMES FOR WHOLE-BODY PET IMAGING

被引:12
作者
DAHLBOM, M
CUTLER, PD
DIGBY, WM
LUK, WK
REED, J
机构
[1] EDWARD MALLINCKRODT INST RADIOL, ST LOUIS, MO 63110 USA
[2] CTI PET SYST, KNOXVILLE, TN 37933 USA
基金
美国国家卫生研究院;
关键词
D O I
10.1109/23.322951
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Whole body PET images suffer from relatively high noise levels due to inherently poor counting statistics in the emission data. Optimization of acquisition parameters is essential, to minimize any additional noise contamination. It has previously been shown that by using a continuous or redundant axial sampling scheme, a reduction in statistical noise and improvement in image quality are possible. In this work, the continuous axial sampling technique is further characterized and compared to the conventional step-and-shoot technique. The main source of additional noise contamination with conventional sampling is the detector sensitivity normalization procedure which is applied to the emission data. With continuous axial sampling and a single normalization matrix for all planes, the statistical noise in the normalized factors is reduced by factor close to the number of planes in the scanner. The continuous sampling technique is shown to be less sensitive to small patient movements (<5 mm) compared to conventional sampling. Previously reported problems of data handling have been resolved by rewriting the acquisition firmware to allow on-line addition of the redundant sampled data in hardware.
引用
收藏
页码:1571 / 1576
页数:6
相关论文
共 9 条
[1]   QUANTITATION IN POSITRON EMISSION COMPUTED-TOMOGRAPHY .7. A TECHNIQUE TO REDUCE NOISE IN ACCIDENTAL COINCIDENCE MEASUREMENTS AND COINCIDENCE EFFICIENCY CALIBRATION [J].
CASEY, ME ;
HOFFMAN, EJ .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1986, 10 (05) :845-850
[2]   HIGH-SENSITIVITY, TOTAL-BODY PET SCANNING USING 3D DATA ACQUISITION AND RECONSTRUCTION [J].
CHERRY, SR ;
DAHLBOM, M ;
HOFFMAN, EJ .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1992, 39 (04) :1088-1092
[3]   METHODS FOR IMPROVING IMAGE QUALITY IN WHOLE-BODY PET SCANNING [J].
DAHLBOM, M ;
YU, DC ;
CHERRY, SR ;
CHATZIIOANNOU, A ;
HOFFMAN, EJ .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1992, 39 (04) :1079-1083
[4]  
HAWKINS RA, 1991, J NUCL MED, V32, P1555
[5]   PET SYSTEM CALIBRATIONS AND CORRECTIONS FOR QUANTITATIVE AND SPATIALLY ACCURATE IMAGES [J].
HOFFMAN, EJ ;
GUERRERO, TM ;
GERMANO, G ;
DIGBY, WM ;
DAHLBOM, M .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1989, 36 (01) :1108-1112
[6]   CANCER-DETECTION WITH WHOLE-BODY PET USING 2-[F-18]FLUORO-2-DEOXY-D-GLUCOSE [J].
HOH, CK ;
HAWKINS, RA ;
GLASPY, JA ;
DAHLBOM, M ;
TSE, NY ;
HOFFMAN, EJ ;
SCHIEPERS, C ;
CHOI, Y ;
REGE, S ;
NITZSCHE, E ;
MADDAHI, J ;
PHELPS, ME .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1993, 17 (04) :582-589
[7]  
REGE S, 1993, CANCER, V74, P82
[8]   PHYSICAL PERFORMANCE OF THE LATEST GENERATION OF COMMERCIAL POSITRON SCANNER [J].
SPINKS, TJ ;
JONES, T ;
GILARDI, MC ;
HEATHER, JD .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1988, 35 (01) :721-725
[9]   PERFORMANCE EVALUATION OF THE POSITRON SCANNER ECAT EXACT [J].
WIENHARD, K ;
ERIKSSON, L ;
GROOTOONK, S ;
CASEY, M ;
PIETRZYK, U ;
HEISS, WD .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1992, 16 (05) :804-813