DEVELOPMENT OF THE SRK/T INTRAOCULAR-LENS IMPLANT POWER CALCULATION FORMULA

被引:772
作者
RETZLAFF, JA [1 ]
SANDERS, DR [1 ]
KRAFF, MC [1 ]
机构
[1] UNIV ILLINOIS,DEPT OPHTHALMOL,CHICAGO,IL 60680
关键词
A-constant; A-scan; anterior chamber depth; axial length; biometry; height formula; intraocular lens power calculation; regression formula; SRK; SRK II; SRK/T; theoretical formula;
D O I
10.1016/S0886-3350(13)80705-5
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
A new implant power calculation formula (SRK/T) was developed using the nonlinear terms of the theoretical formulas as its foundation but empirical regression methodology for optimization. Postoperative anterior chamber depth prediction, retinal thickness axial length correction, and corneal refractive index were systematically and interactively optimized using an iterative process on five data sets consisting of 1,677 posterior chamber lens cases. The new SRK/T formula performed slightly better than the Holladay, SRK II, Binkhorst, and Hoffer formulas, which was the expected result as any formula performs superiorly with the data from which it was derived. Comparative accuracy of this formula upon independent data sets is addressed in a follow-up report. The formula derived provides a primarily theoretical approach under the SRK umbrella of formulas and has the added advantage of being calculable using either SRK A-constants that have been empirically derived over the last nine years or using anterior chamber depth estimates. © 1990, American Society of Cataract and Refractive Surgery. All rights reserved.
引用
收藏
页码:333 / 340
页数:8
相关论文
共 28 条
[1]  
Retzlaff J, A new intraocular lens calculation formula, Am Intra-Ocular Implant Soc J, 6, pp. 148-152, (1980)
[2]  
Sanders DR, Kraff MC, Improvement of intraocular lens power calculation using empirical data, Am Intra-Ocular Implant Soc J, 6, pp. 263-267, (1980)
[3]  
Retzlaff J, Posterior chamber implant power calculation: regression formulas, Am Intra-Ocular Implant Soc J, 6, pp. 268-270, (1980)
[4]  
Gills JP, Minimizing postoperative refractive error, Contact Intraocul Lens Med J, 6, pp. 56-59, (1980)
[5]  
Sanders D, Retzlaff J, Kraff M, Et al., Comparison of the accuracy of the Binkhorst, Colenbrander, and SRK™ implant power prediction formulas, Am Intra-Ocular Implant Soc J, 7, pp. 337-340, (1981)
[6]  
Sanders DR, Retzlaff J, Kraff MC, Comparison of empirically derived and theoretical aphakic refraction formulas, Arch Ophthalmol, 101, pp. 965-967, (1983)
[7]  
Thompson JT, Maumenee AE, Baker CC, A new posterior chamber intraocular lens formula for axial myopes, Ophthalmology, 91, pp. 484-488, (1984)
[8]  
Sanders DR, Retzlaff J, Kraff MC, Comparison of the SRK II™ formula and other second generation formulas, J Cataract Refract Surg, 14, pp. 136-141, (1988)
[9]  
Retzlaff J, Sanders DR, Kraff M, A Manual of Implant Power Calculation, (1988)
[10]  