REPRODUCIBILITY OF MANDIBULAR MOTION AND MUSCLE-ACTIVITY LEVELS USING A COMMERCIAL COMPUTER-RECORDING SYSTEM

被引:26
作者
THROCKMORTON, GS [1 ]
TEENIER, TJ [1 ]
ELLIS, E [1 ]
机构
[1] UNIV TEXAS,SW MED CTR,DIV ORAL & MAXILLOFACIAL SURG,5323 HARRY HINES BLVD,DALLAS,TX 75235
关键词
D O I
10.1016/0022-3913(92)90344-A
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
A commercial computer recording system (BioPak) was tested for its accuracy and reproducibility in recording mandibular motion and muscle activity levels (EMG). Accuracy of measurements of mandibular motion was tested using sliding calipers. Accuracy of muscle activity levels was checked with a sine-wave calibration signal of known amplitude and frequency. Reproducibility of motion and of EMG was made using five control subjects each tested on 3 separate days. Computer measurements of motion were found to require correction for nonlinearity at openings beyond 45 mm. Most maximum voluntary excursions were found to be more reproducible than motions during mastication. However, lateral deviation during opening was strongly affected by magnet orientation and varied greatly between trials. Electromyographic recordings were distorted by improper treatment of high-frequency components of the signal and also varied greatly between trials. This study suggests that the BioPak system may indicate changes in some measures of mandibular motion and EMG levels in patients for whom no changes have occurred.
引用
收藏
页码:348 / 354
页数:7
相关论文
共 23 条
[1]  
ATHANASIOU A E, 1989, International Journal of Adult Orthodontics and Orthognathic Surgery, V4, P239
[2]  
BASMAJIAN JV, 1975, COMPUTERS ELECTROMYO, P118
[3]  
BESSETTE RW, 1989, ORAL MAXILLOFAC SURG, V2, P205
[4]  
Chong-Shan S., 1989, J PROSTHET DENT, V62, P682
[5]   ELECTROMYOGRAPHY OF THE SUPRAHYOID MUSCULATURE FOLLOWING MANDIBULAR ADVANCEMENT WITH AND WITHOUT RIGID FIXATION [J].
ELLIS, E ;
DECHOW, PC ;
CARLSON, DS ;
LAROCHE, V .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1990, 48 (01) :49-53
[6]   AN EVALUATION OF THE CRITERIA USED TO DIAGNOSE MANDIBULAR DYSFUNCTION WITH THE MANDIBULAR KINESIOGRAPH [J].
FEINE, JS ;
HUTCHINS, MO ;
LUND, JP .
JOURNAL OF PROSTHETIC DENTISTRY, 1988, 60 (03) :374-380
[7]   STANDARDIZATION OF ELECTROMYOGRAPHY OF MASSETER MUSCLE IN MAN [J].
FRAME, JW ;
ROTHWELL, PS ;
DUXBURY, AJ .
ARCHIVES OF ORAL BIOLOGY, 1973, 18 (11) :1419-1423
[8]   ELECTROMYOGRAMS ARE REPEATABLE - PRECAUTIONS AND LIMITATIONS [J].
GANS, C ;
GORNIAK, GC .
SCIENCE, 1980, 210 (4471) :795-797
[9]   ELECTROMYOGRAPHY OF MASSETER AND ANTERIOR TEMPORALIS MUSCLES IN PATIENTS WITH TEMPOROMANDIBULAR DYSFUNCTION [J].
GRIFFIN, CJ ;
MUNRO, RR .
ARCHIVES OF ORAL BIOLOGY, 1971, 16 (08) :929-&
[10]   THE KINESIOGRAPHIC MEASUREMENT OF JAW DISPLACEMENT [J].
HANNAM, AG ;
DECOU, RE ;
SCOTT, JD ;
WOOD, WW .
JOURNAL OF PROSTHETIC DENTISTRY, 1980, 44 (01) :88-93