DETERMINING LOCATIONS OF INTRACEREBRAL LESIONS FOR PROTON RADIOTHERAPY

被引:7
作者
LEVIN, CV
HOUGH, J
ADAMS, LP
BOONZAIER, D
RUTHER, H
WYNCHANK, S
机构
[1] UNIV CAPE TOWN,DEPT RADIOTHERAPY,CAPE TOWN,SOUTH AFRICA
[2] MRC,MED BIOPHYS RES INST,PAROW,SOUTH AFRICA
[3] UNIV CAPE TOWN,DEPT MED PHYS,CAPE TOWN,SOUTH AFRICA
[4] UNIV CAPE TOWN,DEPT BIOMED ENGN,CAPE TOWN,SOUTH AFRICA
[5] UNIV CAPE TOWN,DEPT SURVEYING,CAPE TOWN,SOUTH AFRICA
关键词
D O I
10.1088/0031-9155/38/10/002
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Using an external view of the head, the ability to direct a proton radiotherapy beam at an intracerebral lesion is described, using a biostereometric (BSM) technique. The positions of markers, recognizable on computed tomography (CT) or magnetic resonance (MR) images, at known locations on the skin of a patient's head are related to the site of the lesion seen on the images. The markers' positions are determined by a BSM device, incorporating six video cameras coupled to a computer. A transformation from a coordinate system, defined by the CT or MR images, to another coordinate system, that of the Bsm device, allows the proton beam to be directed towards the lesion. Markers used in this work were solid steel spheres for CT and plastic spheres containing oil for MR images.
引用
收藏
页码:1393 / 1401
页数:9
相关论文
共 15 条
[1]  
ADAMS LP, 1990, UNPUB 3 DIMENSIONAL
[2]  
ADAMS LP, 1989, OPTICAL 3 DIMENSIONA
[3]   EVALUATION OF PROTON DENSITY BY MAGNETIC-RESONANCE-IMAGING - PHANTOM EXPERIMENTS AND ANALYSIS OF MULTIPLE COMPONENT PROTON TRANSVERSE RELAXATION [J].
BRIX, G ;
SCHAD, LR ;
LORENZ, WJ .
PHYSICS IN MEDICINE AND BIOLOGY, 1990, 35 (01) :53-66
[4]   RELOCATABLE FRAME FOR STEREOTAXIC EXTERNAL BEAM RADIOTHERAPY [J].
GILL, SS ;
THOMAS, DGT ;
WARRINGTON, AP ;
BRADA, M .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1991, 20 (03) :599-603
[5]   A NONINVASIVE METHOD FOR FRACTIONATED STEREOTACTIC IRRADIATION OF BRAIN-TUMORS WITH LINEAR-ACCELERATOR [J].
HARIZ, MI ;
HENRIKSSON, R ;
LOFROTH, PO ;
LAITINEN, LV ;
SATERBORG, NE .
RADIOTHERAPY AND ONCOLOGY, 1990, 17 (01) :57-72
[6]  
Leksell, 1949, ACTA CHIR SCAND, V99, P229
[7]   COMPUTED LIMITATIONS OF SPOT SCANNING FOR THERAPEUTIC PROTON-BEAMS [J].
LEVIN, CV ;
GONIN, R ;
WYNCHANK, S .
INTERNATIONAL JOURNAL OF BIO-MEDICAL COMPUTING, 1988, 23 (1-2) :33-41
[8]   A SYSTEM FOR STEREOTACTIC RADIOSURGERY WITH A LINEAR-ACCELERATOR [J].
LUTZ, W ;
WINSTON, KR ;
MALEKI, N .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1988, 14 (02) :373-381
[9]  
MUNDINGER F, 1978, APPL NEUROPHYSIOL, V41, P169
[10]  
SCOTT PJ, 1981, PHOTOGRAMM REC, V10, P435