DYNAMIC CALIBRATION OF PEROXYACETYL NITRATE (PAN) ANALYZERS BY ANNULAR DENUDER AND ION-CHROMATOGRAPHIC TECHNIQUES

被引:7
作者
CICCIOLI, P
POSSANZINI, M
DIPALO, V
CECINATO, A
机构
[1] Istituto sull' Inquinamento Atmosferico, CNR, Area della Ricerca di Roma, 00016 Monterotondo Scalo, Via Salaria, km 29.300
来源
ATMOSPHERIC ENVIRONMENT PART A-GENERAL TOPICS | 1992年 / 26卷 / 08期
关键词
PEROXYACETYL NITRATE; DYNAMIC CALIBRATION; ANNULAR DENUDER; ALKALINE HYDROLYSIS;
D O I
10.1016/0960-1686(92)90135-8
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Peroxyacetyl nitrate (PAN) at ppb-ppt levels is produced by irradiating a mixture of acetaldehyde and NO2 dynamically generated by permeation tubes. The quantitative and selective removal of NO2 and ozone from the reaction mixture performed by using two annular denuders allows the quantification of PAN as nitrite by ion chromatography carried out on the hydrolysed sample. The method is suitable for the field calibration of GC-based PAN-analysers.
引用
收藏
页码:1513 / 1518
页数:6
相关论文
共 20 条
[1]   THE MECHANISM OF THE CARBONYL ELIMINATION REACTION OF BENZYL NITRATE - KINETIC ISOTOPE EFFECTS AND DEUTERIUM EXCHANGE [J].
BUNCEL, E ;
BOURNS, AN .
CANADIAN JOURNAL OF CHEMISTRY-REVUE CANADIENNE DE CHIMIE, 1960, 38 (12) :2457-2466
[2]  
DARLEY EF, 1963, ANAL CHEM, V35, P389
[3]   PHOTOCHEMICAL-SYNTHESIS OF PEROXYACYL NITRATES IN GAS-PHASE VIA CHLORINE-ALDEHYDE REACTION [J].
GAY, BW ;
NOONAN, RC ;
BUFALINI, JJ ;
HANST, PL .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1976, 10 (01) :82-85
[4]   PORTABLE GENERATOR FOR ON-SITE CALIBRATION OF PEROXYACETYL NITRATE ANALYZERS [J].
GROSJEAN, D ;
FUNG, K ;
COLLINS, J ;
HARRISON, J ;
BREITUNG, E .
ANALYTICAL CHEMISTRY, 1984, 56 (03) :569-573
[5]   PEROXYACETYL NITRATE - COMPARISON OF ALKALINE-HYDROLYSIS AND CHEMI-LUMINESCENCE METHODS [J].
GROSJEAN, D ;
HARRISON, J .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1985, 19 (08) :749-752
[6]   FIELD COMPATIBLE CALIBRATION PROCEDURE FOR PEROXYACETYL NITRATE [J].
HOLDREN, MW ;
SPICER, CW .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1984, 18 (02) :113-116
[8]   CALIBRATION OF PEROXYACETYL NITRATE MEASUREMENTS WITH AN NOX ANALYZER [J].
JOOS, LF ;
LANDOLT, WF ;
LEUENBERGER, H .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1986, 20 (12) :1269-1273
[9]   AN ASSESSMENT OF THE LUMINOL CHEMILUMINESCENCE TECHNIQUE FOR MEASUREMENT OF NO2 IN AMBIENT AIR [J].
KELLY, TJ ;
SPICER, CW ;
WARD, GF .
ATMOSPHERIC ENVIRONMENT PART A-GENERAL TOPICS, 1990, 24 (09) :2397-2403
[10]   AN AUTOMATED TECHNIQUE FOR THE MEASUREMENT OF PEROXYACETYLNITRATE IN AMBIENT AIR AT PPB AND PPT LEVELS [J].
MULLER, KP ;
RUDOLPH, J .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 1989, 37 (04) :253-262