RISK OF MICROBIAL-CONTAMINATION OF IODINATED CONTRAST-MEDIA ON MULTIPLE-USE OF LARGE-VOLUME BOTTLES

被引:13
作者
DOMINIK, RH
SEGEBADE, IE
TAENZER, V
机构
[1] Department Röntgendiagnostik, Krankenhaus Moabit, 10559 Berlin
[2] Department PH-Qualitätssicherung/Biologische Qualitätsprüfung, Schering AG, 13342 Berlin
关键词
CONTRAST MEDIA; COMPLICATIONS; COMPUTED TOMOGRAPHY; TECHNIQUE; BACTERIA;
D O I
10.1016/0720-048X(94)00593-2
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Large-volume bottles of iodinated contrast material (CM) offer advantages over single-dose vials in respect of handling, radiation protection of personnel, cost and waste. Because non-ionic CM are considered to be susceptible to microbial contamination, the probability of such contamination was investigated under practical conditions with reference to the duration of use. Under conditions identical to those in practice, contamination was found in only about 1% of bottles examined after a single piercing. Under worst-case conditions, a maximum of 9 microorganisms/bottle was found. No pathogen multiplication was observed within 24 h in microbial challenge tests; rather, the nosocomial pathogens examined died quickly in iopromide, the only exception being Pseudomonas aeruginosa. There was not a single case of bacterial multiplication on clinical use of 500-ml infusion bottles in patients undergoing routine computed tomography, using either injection by hand or an automatic infusion device. In conclusion, the microbial count rate did not differ from that of small-volume parenterals used up immediately after piercing. To ensure an adequate safety margin for the avoidance of septicemia or pyrogenic reactions, the CM should be used within 1 examination day.
引用
收藏
页码:198 / 205
页数:8
相关论文
共 27 条
[1]  
Holmes, Allwood, A review: the microbial contamination of intravenous infusions during clinical use, J Appl Bacteriol, 46, pp. 247-267, (1979)
[2]  
Highsmith, Greenhood, Allen, Growth of nosocomial pathogens in multiple-dose parenteral medication vials, J Clin Microbiol, 15, pp. 1024-1028, (1982)
[3]  
Maki, Anderson, Shulman, In-use contamination of intravenous infusion fluid, Appl Microbiol, 28, pp. 778-784, (1974)
[4]  
Dawson, Becker, Holton, The effect of contrast media on the growth of bacteria, Br J Radiol, 56, pp. 809-815, (1983)
[5]  
Lisle, Ratcliffe, Faoagali, Cherian, Bacterial contamination of contrast media stored after opening, Br J Radiol, 63, pp. 532-534, (1990)
[6]  
Tress, Hellyar, Pennington, Thomson, Martinkus, Lavan, Bacteriological studies of open versus closed contrast medium delivery systems in angiography, Australas Radiol, 38, pp. 112-114, (1994)
[7]  
Tress, Hellyar, Pennington, Thomson, Desmond, Martinkus, Lavan, Multiple doses of contrast medium from a single container: bacteriological studies, Australas Radiol, 38, pp. 115-118, (1994)
[8]  
Michaelis, Ruebner, Growth of bacteria in intravenous infusion fluids, The Lancet, 1, (1953)
[9]  
Center For Disease Control, Follow-up on septicemias associated with contaminated intravenous fluids, Morbid Mortal Weekly Rep, 22, (1973)
[10]  
Maki, Martin, Nationwide epidemic of septicaemia caused by contaminated infusion products. IV growth of microbial pathogens in fluids for intravenous infusion, J Infect Dis, 131, pp. 267-272, (1975)