KINETIC FUNDUS PERIMETRY WITH THE SCANNING LASER OPHTHALMOSCOPE

被引:16
作者
ROHRSCHNEIDER, K
BECKER, M
FENDRICH, T
VOLCKER, HE
机构
关键词
FUNDUS PERIMETRY; AMSLER CHART; SCANNING LASER OPHTHALMOSCOPE; FIXATION;
D O I
10.1055/s-2008-1035356
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background The detection of circumscribed visual field defects due to pathologic macular findings may be difficult even when modern conventional perimetry procedures are used. Using conventional clinical methods there exists no reliable correlation between morphology and function for follow-up and documentation. The Laser Scanning Ophthalmoscope enables a fundus-based examination and therefore allows exact comparison between morphologic appearance and corresponding function. Patients and Methods 50 eyes with pathologic macular findings were examined using a newly developed kinetic perimetry method based on the Scanning Laser Ophthalmoscope. The results were compared to those obtained with other clinical examinations such as Goldmann or Octopus visual field and Amsler-chart. Results fundus-based examination with the SLO is preferable for detection especially when small pathologic findings at the posterior pole like macular holes or small serous detachments are combined with reduced stability of fixation. The detection of sharp borders of the scotomas is much better than with conventional perimetry. Conclusion The Scanning Laser Ophthalmoscope allows several different types of fundus-based examinations. Concerning kinetic perimetry we were able to find the borders of scotomas within very short examination times. This method therefore is of valuable help in patients with circumscribed scotomas at the posterior pole combined with deterioration of the stability of fixation and allows documentation for fellow-up and further comparison with Ether clinical findings.
引用
收藏
页码:102 / 110
页数:9
相关论文
共 23 条
[1]   *LEXAMEN QUALITATIF DE LA FONCTION MACULAIRE [J].
AMSLER, M .
OPHTHALMOLOGICA, 1947, 114 (4-5) :248-261
[2]  
Amsler M., 1949, T OPHTHAL SOC UK, V69, P397
[3]  
AUULHORN E, 1972, BER DTSCH OPHTHALMOL, V71, P487
[4]  
EIZENMAN M, 1992, CAN J OPHTHALMOL, V27, P336
[5]   A NEW LASER SCANNING SYSTEM FOR VIDEO OPHTHALMOSCOPY - 1ST CLINICAL-RESULTS WITH AND WITHOUT DIGITAL IMAGE-PROCESSING [J].
FABIAN, E ;
MERTZ, M ;
HOFMANN, H ;
WERTHEIMER, R ;
FOOS, C .
KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 1990, 197 (01) :55-63
[6]  
FABIAN E, 1989, KLIN MONATSBL AUGENH, V196, P4589
[7]  
FLETCHER DC, 1994, INVEST OPHTH VIS SCI, V35, P1553
[8]   *EIN SELBSTREGISTRIERENDES PROJEKTIONSKUGELPERIMETER [J].
GOLDMANN, H .
OPHTHALMOLOGICA, 1945, 109 (2-3) :71-79
[9]  
Plesch A, 1988, Fortschr Ophthalmol, V85, P565
[10]  
RING TM, 1992, OPHTHALMOLOGE S, V89, pS74