A RETRIEVABLE NITINOL VENA-CAVA FILTER - EXPERIMENTAL AND INITIAL CLINICAL-RESULTS

被引:19
作者
NAKAGAWA, N [1 ]
CRAGG, AH [1 ]
SMITH, TP [1 ]
CASTANEDA, F [1 ]
BARNHART, WH [1 ]
DEJONG, SC [1 ]
机构
[1] UNIV IOWA HOSP & CLIN,COLL MED,DEPT MACROMOLEC CHEM,IOWA CITY,IA 52242
关键词
EMBOLISM; PULMONARY; VENAE-CAVAE; FILTERS;
D O I
10.1016/S1051-0443(94)71539-6
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: The authors describe the properties of a new retrievable nitinol vena cava filter and report experimental and initial clinical results. MATERIALS AND METHODS: The filters, made of nitinol monofilament wire that forms a spiral cone and retrieval wire, were introduced through an indwelling 5.5-F transfemoral sheath into the infrarenal portion of the inferior vena cava in 10 sheep. In seven animals, four 4 x 30-mm radiopaque clots were injected below the filter to test its thrombus-trapping efficacy. Aspiration thrombectomy was then attempted, and the filter was removed. Follow-up venography was performed 1 week after placement in three other animals. After successful preclinical testing, the filter was implanted and retrieved in two patients. RESULTS: All 10 filters were successfully and easily placed in sheep. All filters were thrombus-free at follow-up venography. All clots injected in the iliac veins were trapped by the filter and successfully removed by means of aspiration thrombectomy. All 10 filters were retrieved without difficulty. Temporary filter implantation and retrieval were accomplished in two patients for 5 and 7 days. In one patient, infrafilter thrombus was aspirated. Perisheath thrombosis occurred in both patients. One patient subsequently underwent permanent filter placement. CONCLUSION: Temporary vena cava filtration is feasible. Potential advantages include easy placement, surveillance, and retrieval. One current limitation is pericatheter thrombosis, which may be eliminated by a less thrombogenic sheath.
引用
收藏
页码:507 / 512
页数:6
相关论文
共 24 条
  • [1] BUEHLER WJ, 1969, WIRE J, V1, P41
  • [2] BIOCOMPATIBILITY OF NITINOL ALLOY AS AN IMPLANT MATERIAL
    CASTLEMAN, LS
    MOTZKIN, SM
    ALICANDRI, FP
    BONAWIT, VL
    JOHNSON, AA
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1976, 10 (05): : 695 - 731
  • [3] COHEN JR, 1992, CANCER, V70, P1993, DOI 10.1002/1097-0142(19921001)70:7<1993::AID-CNCR2820700731>3.0.CO
  • [4] 2-V
  • [5] A NEW PERCUTANEOUS VENA-CAVA FILTER
    CRAGG, A
    LUND, G
    SALOMONOWITZ, E
    RYSAVY, J
    CASTANEDA, F
    CASTANEDAZUNIGA, W
    AMPLATZ, K
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1983, 141 (03) : 601 - 604
  • [6] NATURAL-HISTORY OF PULMONARY-EMBOLISM
    DALEN, JE
    ALPERT, JS
    [J]. PROGRESS IN CARDIOVASCULAR DISEASES, 1975, 17 (04) : 259 - 270
  • [7] AMPLATZ RETRIEVABLE VENA-CAVAL FILTER
    DARCY, MD
    HUNTER, DW
    LUND, GB
    CARDELLA, JF
    [J]. SEMINARS IN INTERVENTIONAL RADIOLOGY, 1986, 3 (03) : 214 - 219
  • [8] PERCUTANEOUS INFERIOR VENA-CAVAL FILTERS
    DORFMAN, GS
    [J]. RADIOLOGY, 1990, 174 (03) : 987 - 992
  • [9] EXPERIENCE WITH THE AMPLATZ RETRIEVABLE VENA-CAVA FILTER
    EPSTEIN, DH
    DARCY, MD
    HUNTER, DW
    COLEMAN, CC
    TADAVARTHY, SM
    MURRAY, PD
    CASTANEDAZUNIGA, WR
    AMPLATZ, K
    [J]. RADIOLOGY, 1989, 172 (01) : 105 - 110
  • [10] INFERIOR VENA-CAVAL FILTERS - ANALYSIS OF 5 CURRENTLY AVAILABLE DEVICES
    GRASSI, CJ
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1991, 156 (04) : 813 - 821