RAPID ONLINE PRECOLUMN HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC METHOD FOR THE DETERMINATION OF BENOMYL, CARBENDAZIM AND ALDICARB SPECIES IN DRINKING-WATER

被引:13
作者
MARVIN, CH
BRINDLE, ID
HALL, CD
CHIBA, M
机构
[1] AGR CANADA,RES STN,VINELAND STN L0R 2E0,ONTARIO,CANADA
[2] BROCK UNIV,DEPT CHEM,ST CATHARINES L2S 3A1,ONTARIO,CANADA
[3] ONTARIO MINIST ENVIRONM,REXDALE M9W 5L1,ONTARIO,CANADA
来源
JOURNAL OF CHROMATOGRAPHY | 1991年 / 555卷 / 1-2期
关键词
D O I
10.1016/S0021-9673(01)87174-0
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A reversed-phase high-performance liquid chromatographic (HPLC) method has been developed for the determination of trace concentrations of benomyl, carbendazim, aldicarb, aldicarb sulphoxide and aldicarb sulphone in drinking water. A 10-ml sample of water is passed through a 3-cm precolumn, packed with 5-mu-m C8 sorbent, at a flow-rate of 5 ml/min. The HPLC system is then switched to an acetonitrile-water gradient elution program. The preconcentrated analytes are eluted from, and separated by, the 3-cm C8 precolumn and determined by UV absorption. The total analytical time is 25 min. The lowest detectable concentrations are in the range of 2.5 . 10(-9) - 11.0 . 10(-9) g/ml for the five analytes investigated with 10 ml of sample.
引用
收藏
页码:147 / 154
页数:8
相关论文
共 18 条
[1]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF CARBARYL AND 1-NAPHTHOL AT RESIDUE LEVELS IN VARIOUS WATER SOURCES BY DIRECT INJECTION AND TRACE ENRICHMENT [J].
BUSHWAY, RJ .
JOURNAL OF CHROMATOGRAPHY, 1981, 211 (01) :135-143
[2]  
CHAPUT D, 1986, J ASSOC OFF ANA CHEM, V69, P6
[3]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC METHOD FOR SIMULTANEOUS DETERMINATION OF BENOMYL AND CARBENDAZIM IN AQUEOUS-MEDIA [J].
CHIBA, M ;
SINGH, RP .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1986, 34 (01) :108-112
[4]   RAPID SPECTROPHOTOMETRIC METHOD FOR SIMULTANEOUS DETERMINATION OF INTACT BENOMYL AND ITS DEGRADATION PRODUCT, METHYL 2-BENZIMIDAZOLECARBAMATE (MBC), IN ORGANIC-SOLVENTS AND WATER [J].
CHIBA, M .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1977, 25 (02) :368-373
[5]   USE OF BONDED PHASE SILICA SORBENTS FOR THE SAMPLING OF PRIORITY POLLUTANTS IN WASTEWATERS [J].
CHLADEK, E ;
MARANO, RS .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1984, 22 (08) :313-320
[6]   OPTIMIZATION OF PRECOLUMN DESIGN IN LIQUID-CHROMATOGRAPHY [J].
GOEWIE, CE ;
NIELEN, MWF ;
FREI, RW ;
BRINKMAN, UAT .
JOURNAL OF CHROMATOGRAPHY, 1984, 301 (02) :325-334
[7]   USE OF PYROCARBON SORBENTS FOR TRACE ENRICHMENT OF POLAR COMPOUNDS FROM AQUEOUS SAMPLES WITH ONLINE HPLC ANALYSIS [J].
GOLKIEWICZ, W ;
WERKHOVENGOEWIE, CE ;
BRINKMAN, UAT ;
FREI, RW ;
COLIN, H ;
GUIOCHON, G .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1983, 21 (01) :27-33
[8]  
HARVEY MC, 1984, LIQUID CHROMATOGRAPH, P332
[9]   ORGANICS IN WATER - SOLID-PHASE EXTRACTION ON A SMALL-SCALE [J].
JUNK, GA ;
RICHARD, JJ .
ANALYTICAL CHEMISTRY, 1988, 60 (05) :451-454
[10]   PREFERRED EXPERIMENTAL CONDITIONS FOR TRACE ANALYSIS BY MODERN LIQUID-CHROMATOGRAPHY [J].
KIRKLAND, JJ .
ANALYST, 1974, 99 (1185) :859-885