MODIFIED POLY(GLYCIDYL METHACRYLATE-CO-ETHYLENE DIMETHACRYLATE) CONTINUOUS ROD COLUMNS FOR PREPARATIVE-SCALE ION-EXCHANGE CHROMATOGRAPHY OF PROTEINS

被引:180
作者
SVEC, F
FRECHET, JMJ
机构
[1] Cornell University, Department of Chemistry, Baker Laboratory, Ithaca
关键词
D O I
10.1016/0021-9673(94)01021-6
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A continuous rod of porous poly(glycidyl methacrylate-co-ethylene dimethacrylate) has been prepared by a free radical polymerization within the confines of a 300 x and mm I.D. chromatographic column. The epoxide groups of the rod have been modified by a reaction with diethylamine that affords ionizable functionalities required for the ion-exchange chromatographic mode. The properties of this rod column have been characterized and the column has been used successfully for the chromatographic separation of proteins. The column exhibits a dynamic capacity that exceeds 300 mg at a flow velocity of 200 cm/min. An excellent selectivity allows the separation of up to 300 mg of a protein mixture in a single run.
引用
收藏
页码:89 / 95
页数:7
相关论文
共 22 条
[1]   PERFUSION CHROMATOGRAPHY PACKING MATERIALS FOR PROTEINS AND PEPTIDES [J].
AFEYAN, NB ;
FULTON, SP ;
REGNIER, FE .
JOURNAL OF CHROMATOGRAPHY, 1991, 544 (1-2) :267-279
[2]   FLOW-THROUGH PARTICLES FOR THE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC SEPARATION OF BIOMOLECULES - PERFUSION CHROMATOGRAPHY [J].
AFEYAN, NB ;
GORDON, NF ;
MAZSAROFF, I ;
VARADY, L ;
FULTON, SP ;
YANG, YB ;
REGNIER, FE .
JOURNAL OF CHROMATOGRAPHY, 1990, 519 (01) :1-29
[3]   DESIGN AND PREPARATION OF NOVEL PARTICULATE AND CONTINUOUS POLYMERIC MACROPOROUS MEDIA FOR THE SEPARATION OF BIOLOGICAL AND SYNTHETIC MOLECULES [J].
FRECHET, JMJ .
MAKROMOLEKULARE CHEMIE-MACROMOLECULAR SYMPOSIA, 1993, 70-1 :289-301
[4]   VERY HIGH-SPEED SEPARATION OF PROTEINS WITH A 20-MU-M REVERSED-PHASE SORBENT [J].
FULTON, SP ;
AFEYAN, NB ;
GORDON, NF ;
REGNIER, FE .
JOURNAL OF CHROMATOGRAPHY, 1991, 547 (1-2) :452-456
[5]   MEMBRANE CHROMATOGRAPHIC SYSTEMS FOR HIGH-THROUGHPUT PROTEIN SEPARATIONS [J].
GERSTNER, JA ;
HAMILTON, R ;
CRAMER, SM .
JOURNAL OF CHROMATOGRAPHY, 1992, 596 (02) :173-180
[6]   HIGHLY PERMEABLE OPEN-PORE POLYURETHANE COLUMNS FOR LIQUID-CHROMATOGRAPHY [J].
HANSEN, LC ;
SIEVERS, RE .
JOURNAL OF CHROMATOGRAPHY, 1974, 99 (NOV6) :123-133
[7]   REVERSED-PHASE CHROMATOGRAPHY OF PROTEINS AND PEPTIDES ON COMPRESSED CONTINUOUS BEDS [J].
HJERTEN, S ;
NAKAZATO, K ;
MOHAMMAD, J ;
EAKER, D .
CHROMATOGRAPHIA, 1993, 37 (5-6) :287-294
[8]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY ON CONTINUOUS POLYMER BEDS [J].
HJERTEN, S ;
LIAO, JL ;
ZHANG, R .
JOURNAL OF CHROMATOGRAPHY, 1989, 473 (01) :273-275
[9]   REACTIVE POLYMERS .48. SYNTHESIS OF POLYMERIC SORBENTS WITH CARBOXYLIC GROUPS BY CHEMICAL-REACTIONS OF THE COPOLYMER DIHYDROXYPROPYL METHACRYLATE ETHYLENE DIMETHACRYLATE [J].
HRADIL, J ;
SVEC, F .
REACTIVE POLYMERS, 1985, 3 (02) :91-99
[10]   APPLICATION OF CELLULOSIC FAST-FLOW COLUMN FILTERS TO PROTEIN IMMOBILIZATION AND RECOVERY [J].
KENNEDY, JF ;
PATERSON, M .
POLYMER INTERNATIONAL, 1993, 32 (01) :71-81