FOCUSING OF X-RAYS BY CAPILLARY SYSTEMS

被引:24
作者
DABAGOV, SB
NIKITINA, SV
KUMAKHOV, MA
IBRAIMOV, NS
VARTANIANTS, GA
NIKITIN, AN
SPIELBERGER, L
机构
[1] MOSCOW ROENTGEN OPT SYST INST,MOSCOW,RUSSIA
[2] UNIV FRANKFURT,INST KERNPHYS,W-6000 FRANKFURT,GERMANY
关键词
D O I
10.1016/0168-583X(95)00574-9
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The structure and form of the focal spot when focusing X-rays in the energy range from 7 keV to 10 keV by Kumakhov lenses were investigated. It is shown that owing to focusing the radiation concentration abruptly increased. For the first time the interference structure of a focal spot came to light. Possibilities of using a Kumakhov lens as an analyzer with high spectral resolution and as a point source of X-ray radiation are discussed.