HPLC DETERMINATION OF ETHOXYLATED ALCOHOL SURFACTANTS IN WASTEWATER

被引:68
作者
SCHMITT, TM
ALLEN, MC
BRAIN, DK
GUIN, KF
LEMMEL, DE
OSBURN, QW
机构
[1] BASF CORP,WYANDOTTE,MI
[2] CONOCO INC,PONCA CITY,OK 74601
[3] PROCTER & GAMBLE CO,CINCINNATI,OH 45239
[4] SHELL DEV CO,HOUSTON,TX 77001
关键词
D O I
10.1007/BF02540636
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
High performance liquid chromatography (HPLC) may be used for analysis of municipal wasterwater containing ethoxylated alcohol surfactants. After cleanup of the sample by XAD-2 resin, liquid-liquid extraction, ion exchange and cobalt thiocyanate extraction, the surfactant is derivatized with phenyl isocyanate to permit UV detection and analyzed by both normal phase and reversedphase HPLC. The alkyl chain length distribution is determined using reversed-phase HPLC, while the ethoxy chain length is determined by normal phase HPLC. The limit of quantification is 0.1 ppm. © 1990 AOCS Press.